GarrettCom Magnum 700X manual Rpm-Dte, RPM-FST Fiber ST, Twist-lock Connector, Magnum RPM-FST

Page 15
Magnum RPM-DTE
1
2
1 Partition LED
2 Receive LED
Standard 15-pin male "AUI"

Magnum 700X Mini-Concentrators

Installation and User Guide (05/98)

 

 

2.3.3RPM-DTE

The Magnum RPM-DTE is a module equipped with a 15-pin male DTE connector with lock posts. (The RPM-DTE is a mating connector for the RPM-AUI which has a 15-pin female connector and slide locks. The pin

assignments of the two are the same). The RPM-DTE card is designed to support direct

connections (no transceiver required) using

AUI drop cables to any device that is equipped with an AUI port. Examples of

such devices include servers, routers, bridges, hubs, and UNIX workstations.

2.3.4

RPM-FST (Fiber ST, Twist-lock Connector)

 

The Magnum RPM-FST is a multi-mode fiber optic module equipped with a dual ST-

type connector. It functions as an IEEE 802.3 full repeater to support 10BASE-FL and FOIRL network segments. When used for 10BASE-FL segments, this module supports fiber optic

transmission distances up to 2000m. For

10BASE-FL, FOIRL

FOIRL applications, it supports fiber

ST Connectors

 

segments of up to 1000m in length. The

 

RPM-FST includes full transceiver

 

functionality and does not require an external

1

2

transceiver device. In addition to Partition

 

(PART) and Receive (RX) LEDs, a LINK

3

 

LED indicates proper connectivity with the

1 LINK 2 Partition 3 Receive

 

remote device.

Magnum RPM-FST

NOTE: The RPM-FST circuit board contains a six pin jumper which controls the intensity of the transmitted signal. By default, the jumper is placed across pins 5 & 6. The jumper may be set as follows, to accommodate distances of up to 4 km:

(continued on next page)

GARRETT

10

Image 15
Contents Magnum 700X Mini-Concentrator Trademarks Magnum Mini-Concentrator Installation and User GuideContacting Garrett Communications Phone 510Introduction Table of ContentsMagnum  Specifications Packaging Technical Specifications, ConnectorsLED Indicators on Chassis WarrantySpecifications Bridge Port Modules BPMs Specifications Repeater Port Modules RPMsOrdering Information Magnum 700X Mini-Concentrator Introduction Inspecting the Package and ProductProduct Description 1 Magnum 700X Mini-Concentrator Magnum 700X ChassisMagnum 700X Repeater Port Modules RPMs RPM-DTE, RPM-FST, RPM-FSC, RPM-TP, & PM-FPRPM-BNC RPM-AUI Magnum RPM-BNCPin Function 2 AUI Pin AssignmentsRPM-FST Fiber ST, Twist-lock Connector RPM-DTEMagnum RPM-FST 3 km RPM-FSC Fiber SC, Snap-in ConnectorConnector Magnum RPM-FSC RPM-SMF Single-mode Fiber Jumper Across Distances Supported10 km Not usedPM-FP Proper cooling air flow, and for safety Magnum PM-FPRPM-TP Twisted Pair Magnum RPM-TPPage BPM-AUI BPM-FSTMagnum BPM-FST Transceiver functionality. The Link Wiring STP of 150m 500 ft.. ThisBPM-TP Module is designed with internalOptional Bridge Port Modules BPMs Front Mounted Connectors and LEDsInternal Universal Power Supply with Auto-ranging RPMs Repeater Port Modules for All Standard Ethernet MediaIeee Standard Reference Max. Distance Taps PM Type ApplicationsLocating Magnum 700X Mini-Concentrators InstallationConnecting Ethernet Media Media Ieee Standard Connector PM typeConnecting ThinNet 10BASE2 BNC Connecting ThickNet 10BASE5 AUIConnecting Drop Cable 10BASE5 DTE Connecting Single-Mode Fiber Optic SMF Connecting Fiber Optic SC-type, Snap-inRemoving the PM Face Plate Connecting Twisted Pair RJ-45, Unshielded or ShieldedPower Supply Align the connector Pins on the PM card Installing PM CardsInstalling the PM Card Connector socket slotRemoving PM Cards Operation Repeater FunctionalityBPM Local Bridge Functionality Written there. This happens when a Cases where an internal packet is filteredWhen the packet’s source is external, it 2c and 4.2d respectively. When an2d External Packet Filtered 12.2e Local Isolation with Bridge Port Module Powering the Magnum 700X Mini-ConcentratorChassis LEDs Magnum 700X chassis unit LEDsPM LEDs Before Calling for Assistance TroubleshootingReturn Material Authorization RMA Procedure When Calling for AssistanceShipping and Packaging Information No Problem FoundAppendix a Warranty Information