GarrettCom 6K32 manual Contacting GarrettCom, Inc, Canadian Emission, Table of Contents

Page 3

Magnum 6K32 Managed Switch Installation and User Guide (05/05)

Contacting GarrettCom, Inc

Please use the mailing address, phone and fax numbers and email address listed

below:

GarrettCom, Inc.

 

213 Hammond Ave.

 

Fremont, CA 94539

 

Phone (510) 438-9071

 

Fax (510) 438-9072

 

Website: http://www.GarrettCom.com

 

email support@garrettcom.com

 

Federal Communications Commission

 

Radio Frequency Interference Statement

This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.

Canadian Emission

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil respecte toutes les exigences du Réglement sur le matériel du Canada. Cet appareil est Classe A.

TABLE OF CONTENTS

Page

1.0 SPECIFICATIONS

1

www . GarrettCom . com

 

ii

Image 3
Contents Corporate Headquarters GarrettCom, IncTrademarks Table of Contents Contacting GarrettCom, IncCanadian Emission Introduction Troubleshooting Personal Hubs, 10Mb series Personal Switches, 10/100MbTechnical Specifications DC Power Supply Options Fiber connector types supportedManagement Console connector Power Supply InternalAlarm Contact Optional Manual switches for modular slot port module onlyAgency Approvals Ordering Information Gigabit Transceiver options 6KP8-45-2MT 6KP8-45-2SLC LC connectorsIntroduction Inspecting the Package and Product Product Description Magnum 6K32 Managed Switch Magnum 6K32 and 6K32R chassis Mode for best fiber distance Eight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb fiber100Mb fiber eight Port modules for the Magnum Eight-Port Copper Module, 6K8-RJ45 @ RJ-45 + 2@ 100Mb SC@ RJ-45 + 2@ 100Mb ST Four-Port 10 Mb mm Fiber ST Modules Packet Prioritization, 802.1p QOS Gigabit 1000Mbps port modulesFrame Buffering and Flow Control Managed Network Software MNS-6K for Magnum 6K32 Features and Benefits „ Managed switching for high performance Ethernet LANs„ Features Fiber-Built-In Applications Example 1 Magnum 6K32 Switch for a Vlan applicationInternet Internet Example 3 Redundant ApplicationSwitch #1 Installation Locating Magnum 6K32 SwitchesConnecting Ethernet Media Copper Connecting Fiber Optic ST-type, twist-lockConnecting Fiber Optic SC-type, Snap-In Ieee Standard Media Type Max. Distance Port Module FiberMedia Ieee Standard Connecting Single-Mode Fiber OpticTable-Top or Shelf Mounting Rack-mounting for 19 Retma racks, regular Magnum 6K32sMagnum 6K32 unit. These 1 Mountings for Magnum 6K32 units rack-mounted in a frame Rack-mounting, Reverse version of the Magnum 6K32s2 Reverse Magnum 6K32 units, rack- mounted in a frame Powering the Magnum 6K32 Managed SwitchPreparation for Installing and Removing 6KPMs 6K32 Port Module 6KPM Installation1a Removing front panel after the screws being removed Remove Chassis Cover1b Pulling out the top coved from the chassis base 1d Top View 6KPM retaining screws hold Face Plate Installing 6KPM Cards in the Magnum 6K32Securely latching up 6KPM Cards into a Magnum 6K32 Removing 6KPM Cards 2g Top View 6KPM Module installed inside a 6K32 SwitchRemoving a 6KPM Card Console DB-9 Port Connecting the Console Terminal to Magnum 6K32 ManagementPin Signal Description DB-9 Console port connectorFiltering and Forwarding Switching FunctionalityACT Status LEDsAuto-Cross MDIXAuto-negotiation, for 10/100Mbps RJ-45 ports PWRWww . GarrettCom . com Flow-control, Ieee 802.3x standard ’cvr 6KP4Magnum 6K32 Managed Switch Port Modules 6KPM Module Description 1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST twist lock Module Flstfx is a combo fiber Connectors and configuredAs 10Mb Half-duplex by Default for 10Mb fiber Magnum 6KP4Provides an advantage Through combining copper Mode SC-type connectors. ItEquipped with 4 dual speed Copper ports and 2 SingleWww . GarrettCom . com Port@ 100Mbps Multi-Mode Fiber port Activity FULL/HALFLink Placing more ports on one module Magnum 6KP8-45MTModule is a combo module with Copper and fiber Small Form Factor9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port 10a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector11a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector 12 6KM-BLNK@ 1000Mb Fiber SC + 2@ 100Mb SC Before Calling for Assistance When Calling for AssistanceNo Problem Found Return Material Authorization RMA ProcedureShipping and Packaging Information Appendix B Internal DC Power Supply OptionsB1.0 Specifications for Magnum 6K32 SWITCHES, DC Power Power Supply Internal -48VDC OptionB3.0 Applications for DC Powered Switches Power Supply Internal 125 VDC Option Industrial ApplicationsB4.0 Installation B4.1 UL Requirements for DC-powered unitsB5.0 Operation B6.0 Ordering Information B7.0 TroubleshootingGND Appendix C Internal DC Dual-Source Power OptionC5.0 Installation C4.0 Features and Benefits of the DUAL-SOURCE DesignExample Magnum 6K32R-24VDC or Magnum 6K32R-125VDC C5.1 UL RequirementsC6.0 Ordering Information Example Magnum 6K32R-48VDC