GarrettCom 6K32 Status LEDs, Auto-Cross MDIXAuto-negotiation, for 10/100Mbps RJ-45 ports, Pwr

Page 41

Magnum 6K32 Managed Switch

Installation and User Guide (02/05)

Address Learning

All Magnum 6K32 units have address table capacities of 4K node addresses suitable for use in larger networks. They are self-learning, so as nodes are added, removed or moved from one segment to another, the 6K32 Switch automatically keeps up with node locations.

An address-aging algorithm causes least-used addresses to fall out in favor of frequently-used addresses. To reset the address buffer, cycle power down-and-up.

4.2Status LEDs

For all Magnum 6K32 models :

PWR

: Power LED, ON when external power is applied to the unit.

LK

: Steady ON, Link status for 10 Mbps and 100Mbps operation.

ACT

: ON with port activity for 10 Mbps and 100Mbps operation.

F/H

: Full / Half duplex LED, ON when the port is running full

 

duplex, OFF for half duplex.

100/10

: Speed LED, ON when the speed is 100Mbps , OFF when the

 

speed is 10 Mbps

4.3Up-link Cross-over Switch on RJ-45 port modules, for port#1 only

The modular slot provided on Magnum 6K32 managed switch can be filled

with 6KP8-RJ45 port module among all the multiple choices of port modules. The upper part of the copper port module (6KP8-RJ45) has a manual Up-link switch, located on the inside of the unit on the port module board next to the RJ45 port # 1 which it controls. It enables the port’s cable to be cascaded (X) to a 10/100Mb repeater or switching hub in the network. The manual Up-link switch position is configured as (=) position as default factory setting, where used for all-copper module or combo modules.

4.4Auto-Cross (MDIX)Auto-negotiation, for 10/100Mbps RJ-45 ports

The 24 RJ-45 ports on Magnum 6K32 supports auto-cross (MDI or MDIX) in the auto-negotiation mode according to the IEEE 802.3u standard. No crossover cables are needed when connecting the 6K32’s 10/100 copper ports to other unmanaged switches, legacy hubs, managed switches, media-converters etc. Please note that there can be conditions with managed switches where the switch manager fixes the port settings via software, and the result of the auto-negotiation is changed in the managed switch by the manager commands. In such cases, the 10/100 speed or the F/H mode may be affected, but auto-cross in the 6K32 Switches will still work. The auto-cross function can be disabled, if fixed the port at 10 or 100Mb through software..

www . GarrettCom . com

35

Image 41
Contents Corporate Headquarters GarrettCom, IncTrademarks Canadian Emission Table of ContentsContacting GarrettCom, Inc Introduction Troubleshooting Personal Hubs, 10Mb series Personal Switches, 10/100MbTechnical Specifications Management Console connector Fiber connector types supportedPower Supply Internal DC Power Supply OptionsAgency Approvals Alarm Contact OptionalManual switches for modular slot port module only Ordering Information Gigabit Transceiver options 6KP8-45-2MT 6KP8-45-2SLC LC connectorsIntroduction Inspecting the Package and Product Product Description Magnum 6K32 Managed Switch Magnum 6K32 and 6K32R chassis 100Mb fiber eight Port modules for the Magnum Mode for best fiber distanceEight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb fiber @ RJ-45 + 2@ 100Mb ST Eight-Port Copper Module, 6K8-RJ45@ RJ-45 + 2@ 100Mb SC Four-Port 10 Mb mm Fiber ST Modules Packet Prioritization, 802.1p QOS Gigabit 1000Mbps port modulesFrame Buffering and Flow Control Managed Network Software MNS-6K for Magnum 6K32 „ Features Fiber-Built-In Features and Benefits„ Managed switching for high performance Ethernet LANs Applications Example 1 Magnum 6K32 Switch for a Vlan applicationInternet Internet Example 3 Redundant ApplicationSwitch #1 Connecting Ethernet Media InstallationLocating Magnum 6K32 Switches Connecting Fiber Optic SC-type, Snap-In Connecting Fiber Optic ST-type, twist-lockIeee Standard Media Type Max. Distance Port Module Fiber CopperMedia Ieee Standard Connecting Single-Mode Fiber OpticMagnum 6K32 unit. These Table-Top or Shelf MountingRack-mounting for 19 Retma racks, regular Magnum 6K32s 1 Mountings for Magnum 6K32 units rack-mounted in a frame Rack-mounting, Reverse version of the Magnum 6K32s2 Reverse Magnum 6K32 units, rack- mounted in a frame Powering the Magnum 6K32 Managed SwitchPreparation for Installing and Removing 6KPMs 6K32 Port Module 6KPM Installation1a Removing front panel after the screws being removed Remove Chassis Cover1b Pulling out the top coved from the chassis base 1d Top View 6KPM retaining screws hold Face Plate Installing 6KPM Cards in the Magnum 6K32Securely latching up 6KPM Cards into a Magnum 6K32 Removing 6KPM Cards 2g Top View 6KPM Module installed inside a 6K32 SwitchRemoving a 6KPM Card Pin Signal Description Connecting the Console Terminal to Magnum 6K32 ManagementDB-9 Console port connector Console DB-9 PortFiltering and Forwarding Switching FunctionalityAuto-Cross MDIXAuto-negotiation, for 10/100Mbps RJ-45 ports Status LEDsPWR ACTWww . GarrettCom . com Flow-control, Ieee 802.3x standard ’cvr 6KP4Magnum 6K32 Managed Switch Port Modules 6KPM Module Description 1b 6KP4-F10ST, 4@10Mb multi-mode FX-ST twist lock Module As 10Mb Half-duplex by Default for 10Mb fiber Connectors and configuredMagnum 6KP4 Flstfx is a combo fiberEquipped with 4 dual speed Mode SC-type connectors. ItCopper ports and 2 Single Provides an advantage Through combining copperWww . GarrettCom . com Link Port@ 100Mbps Multi-Mode Fiber portActivity FULL/HALF Module is a combo module with Magnum 6KP8-45MTCopper and fiber Small Form Factor Placing more ports on one module9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port 10a 6KP8-45-2LC, 6@ 10/100Mbps RJ-45 and 2@100Mb single-mode FX , LC Small-Form-Factor GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector@ 1000Mb Fiber SC + 2@ 100Mb SC 11a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector12 6KM-BLNK Before Calling for Assistance When Calling for AssistanceNo Problem Found Return Material Authorization RMA ProcedureB1.0 Specifications for Magnum 6K32 SWITCHES, DC Power Appendix B Internal DC Power Supply OptionsPower Supply Internal -48VDC Option Shipping and Packaging InformationB3.0 Applications for DC Powered Switches Power Supply Internal 125 VDC Option Industrial ApplicationsB5.0 Operation B4.0 InstallationB4.1 UL Requirements for DC-powered units B6.0 Ordering Information B7.0 TroubleshootingGND Appendix C Internal DC Dual-Source Power OptionC5.0 Installation C4.0 Features and Benefits of the DUAL-SOURCE DesignC6.0 Ordering Information C5.1 UL RequirementsExample Magnum 6K32R-48VDC Example Magnum 6K32R-24VDC or Magnum 6K32R-125VDC