Falcon FN4KRM-2TXI, FN6KRM-2TXI, FN3KRM-2TXI manual

Page 13

4.8 System Installation Wiring Diagram (single rackmount UPS system)

4.9 System Installation Wiring Diagram (typical multiple parallel UPS units, Rackmount)

4.10 UPS & Transformer Modules Communications Bus Cabling

Use one UA88385 parallel communications bus cabling kit for each UPS to be connected to the system output trans- former module or to paralleled UPS systems. Connect the supplied cables as shown below. Note the first and last con- nectors on the first and last UPS are connected using the longer of the supplied cables. Switch on the termination resis- tor dip switch next to the long cable. For the transformer module, daisy chain the cables from the UPS to the transformer module in a similar manner using the communications connectors located on the transformer module rear panel.

13

Image 13
Contents Owners Operating Manual Table of Contents FN -2TXI Model Double Conversion On-line UPS Block Diagram FN SeriesTM Parallelable and N+1 Redundant UPS FeaturesStorage and Transportation InstallationFN Rackmount Overview Introduction Manual OverviewDC/DC Converter Input & Power Factor CorrectionDC/AC Inverter Internal Battery Charger Battery PacksStatic Bypass Function Automatic Bypass TransfersFN Rackmount UPS Module FNBRM-1S7 Battery Module Unpacking the UPS and Battery BankFNITRM-2 Rackmount Output Transformer Module System unit receivedFloor Loading Requirements PRE-INSTALLATION DetailsUPS Input/Output Requirements UPS Input Power RequirementsFN Rackmount System Rear Panel Overview UPS Output Rating DetailsPage Page Page Control Button and LCD Locations Display & ControlsControl Button Operation Control PanelLED Display Modes LCD Display Overview Status and Error Code DescriptionsLCD Icon Descriptions Page Operation How to start up the UPS with utility power presentPage How to completely shutdown the UPS How to display readings Page How to Display Programmed Settings Page Fixed or constant frequency How to Change the Programmed Settings Page Page Shows the UPS unit address. If Page Models CommunicationsAdvanced Communications Option Cards Available UPS & PC Computer DB-9 pin designations are as followsUPS Side RS-232C Interface Computer Side Optional Remote Emergency Power Off RepoOptional Communications Interface Board Details UA88383 Dry Contact Interface Option Card UA88382 USB Interface Option CardUsha SNMP/HTTP Agent Option Card UPS and Battery Care MaintenanceParallel Mode Operation Environmental Recycling the Used Battery PacksFCC Considerations Requesting Technical Information or Support Technical SupportFalcon ELECTRIC, INC NEW Product Limited WarrantyFN SeriesTM UPS Plus 3kVA 12kVA FN SeriesTM UPS Plus 4kVA 16kVA FN SeriesTM UPS Plus 5kVA 20kVA FN SeriesTM UPS Plus 6kVA 24kVA