Falcon FN4KRM-2TXI, FN6KRM-2TXI, FN3KRM-2TXI manual LED Display Modes

Page 16

Next Page Button

1.When the LCD display is in “Normal Mode”, repeated pressing of this button will sequence down through the input/output/battery parameters and readings.

2.When the UPS is displaying “OFF” or “BPS”, depressing the “Next Page” and “Function” buttons at the same time will place the UPS into “Programming Mode”. Refer to the “How to Change the Programmed Settings” section of this manual for more details.

3.When in “Programming Mode”, repeated pressing of this button will sequentially select the various programmable parameters. Refer to page 27, “How to Change the Programmed Settings” section of this manual for more details.

Confirm Button

1.When in “Programming Mode” and prompted on the LCD display to SAVE settings, pressing this button will save all changed parameters.

5.3 LED Display Modes

Utility (AC Source 1) UPS Input Power Present LED (Green) -- Indicates utility power is present and the UPS input circuit breakers is turned on. If the utility voltage is out of tolerance the LED will turn off.

Bypass (AC Source 2) Bypass Input Power Present LED (Green)-- Indicates bypass power is present and the Bypass circuit breaker is turned on. If bypass power is out of range, the LED will turn off.

N+1 Mode Enabled (Green) - Indicates multiple UPS units are connected in parallel and have been properly configured and programmed for Parallel N+1 mode operation.

Economy/Green Mode Enabled (Yellow) -- Indicates Economy/Green mode has been enabled.

Alarm Condition Present (Red) -- Indicates the UPS in an alarm condition.

16

Image 16
Contents Owners Operating Manual Table of Contents FN SeriesTM Parallelable and N+1 Redundant UPS Features FN -2TXI Model Double Conversion On-line UPS Block DiagramInstallation Storage and TransportationIntroduction Manual Overview FN Rackmount OverviewDC/DC Converter Input & Power Factor CorrectionDC/AC Inverter Battery Packs Internal Battery ChargerStatic Bypass Function Automatic Bypass TransfersUnpacking the UPS and Battery Bank FN Rackmount UPS Module FNBRM-1S7 Battery ModuleFNITRM-2 Rackmount Output Transformer Module System unit receivedPRE-INSTALLATION Details Floor Loading RequirementsUPS Input Power Requirements UPS Input/Output RequirementsUPS Output Rating Details FN Rackmount System Rear Panel OverviewPage Page Page Display & Controls Control Button and LCD LocationsControl Button Operation Control PanelLED Display Modes LCD Display Overview Status and Error Code DescriptionsLCD Icon Descriptions Page How to start up the UPS with utility power present OperationPage How to completely shutdown the UPS How to display readings Page How to Display Programmed Settings Page Fixed or constant frequency How to Change the Programmed Settings Page Page Shows the UPS unit address. If Page Communications ModelsAdvanced Communications Option Cards Available UPS & PC Computer DB-9 pin designations are as followsUPS Side RS-232C Interface Computer Side Optional Remote Emergency Power Off RepoOptional Communications Interface Board Details UA88383 Dry Contact Interface Option Card UA88382 USB Interface Option CardUsha SNMP/HTTP Agent Option Card Maintenance UPS and Battery CareParallel Mode Operation Environmental Recycling the Used Battery PacksFCC Considerations Technical Support Requesting Technical Information or SupportNEW Product Limited Warranty Falcon ELECTRIC, INCFN SeriesTM UPS Plus 3kVA 12kVA FN SeriesTM UPS Plus 4kVA 16kVA FN SeriesTM UPS Plus 5kVA 20kVA FN SeriesTM UPS Plus 6kVA 24kVA