Specifications

 

Transformer

 

 

Filter

“AVR”

Charger

Inverter

 

 

 

 

 

 

 

 

Battery

 

 

 

 

 

 

Figure 30. Block Diagram

 

 

Table 10. Low-Voltage Model Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Levels

 

 

AC Input

 

Output on Battery Power

Model Number

 

(Rated at

 

Nominal

Voltage

 

Frequency

Voltage3

Frequency

 

 

Nominal Inputs)

 

Voltage

Range1

 

Range2

PW5130L1250-XL2U

 

1250 VA, 1150W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PW5130L1750-XL2U

 

1750 VA, 1600W

 

 

 

 

47–70 Hz (50 Hz

 

 

 

 

 

 

 

 

 

 

 

PW5130L2500-XL2U

 

2500 VA, 2250W

 

120V

89–151V

 

system),

120V

50/60 Hz

 

 

 

56.5–70 Hz (60 Hz

(+6/-10%)

±0.1%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PW5130L3000-XL2U

 

2880 VA, 2700W

 

 

 

 

system)

 

 

 

 

 

 

 

 

 

 

 

PW5130L3000-XL3U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1The high and low thresholds can be adjusted using the UPS Configuration tool (see page 43).

2 Up to 40 Hz in low-sensitivity mode (programmable using the UPS Configuration tool). 3 Adjustable to 100V (10% derating of output power) 120/127V.

EATON Powerware® 5130 Rack/Tower UPS (1250–3000 VA) User’s Guide S 164201730 Rev 2

51

www.powerware.com

 

Image 57
Contents Powerware 5130 Rack/Tower UPS 1250-3000 VA User’s Guide Requesting a Declaration of Conformity Class B EMC Statements High-Voltage Models Class a EMC Statements Low-Voltage ModelsSpecial Symbols Table of Contents Warranty Specifications TroubleshootingChapter Introduction Backed by worldwide agency approvals Important Safety Instructions N G E RR N I N G U T I O N Vigtige Sikkerhedsanvisninger GEM Disse AnvisningerSikkerhedsanvisninger R EV a R S E L Belangrijke Veiligheidsinstructies Bewaar Deze InstructiesBelangrijke Veiligheidsinstructies V a a RG E L E T Tarkeita Turvaohjeita Tärkeitä Turvaohjeita Suomi Säilytä Nämä OhjeetA R a R O I T U SConsignes de sécurité Consignes DE Sécurité Importantes Conserver CES InstructionsSicherheitswarnungen Wichtige Sicherheitsanweisungen AufbewarenR N U N G H T U N GR I C O L O Avvisi di sicurezzaT E N Z I O N E V E R T E N Z aViktige Sikkerhetsinstruksjoner Gjem Disse Instruksjonene Viktig SikkerhetsinformasionR L I G R S I K T I G Instruções DE Segurança Importantes Guarde Estas InstruçõesRegulamentos de Segurança I D a D OR I G O Предупреждения по мерам безопасностиОпасно Осторожно ПредупреждениеAdvertencias de Seguridad L I G R OV E R T E N C I a E C a U C I Ó N Viktiga Säkerhetsföreskrifter Spara Dessa FöreskrifterSäkerhetsföreskrifter R aK T I G T Inspecting the Equipment Chapter InstallationUPS Accessory Kit Checking the Accessory KitItemDescription 2U models onlyAdditional High-Voltage Model Accessory Items EBM Accessory ItemsVA models only Connecting the Internal Battery Connectors Connecting the UPS Internal BatteryRackmount Setup UPS SetupInstalling the Rail Kit Tower Setup Continue to the following section, Installing the UPS Installing the Joining Brackets UPS Installation with Four EBMs Installing the UPSInstalling a Communication Cable Installing the Power and Equipment Cords High-voltage only RPO/ROO Connection RPO and ROO InstallationContact 1750 VA, Low-Voltage Rear Panel UPS Rear PanelsRear Panel Turning the UPS On Chapter OperationTurning the UPS Off Starting the UPS on BatteryUPS Front Panel Operating ModesBattery Mode USB Port Additional UPS FeaturesUSB Port Pin Number Function Contact Communication Port optionalProgrammable Receptacle Load Segments PowerShareFunction Factory Setting Other Available Settings Customizing the UPS with the UPS Configuration ToolMain Output Options Voltage Threshold OptionsBattery Options UPS Sensitivity OptionsUPS On/Off Options Transporting the UPS UPS and Battery CareWhen to Replace Batteries Storing the UPS and BatteriesReplacing Batteries How to Replace Internal Batteries Unscrew and remove the metal battery cover see Figure How to Replace Extended Battery Modules Recycling the Used Battery or UPS Low-Voltage Model Specifications Weights and Dimensions High-Voltage Model SpecificationsPower Levels Dimensions WxHxD WeightPower Connections EBM Model Number Dimensions WxHxD WeightModel Battery Environmental and SafetyHalf Load Battery Runtimes+1 EBM +2 EBMs +3 EBMs +4 EBMs Full LoadSpecifications Alarm Indicators Audible Alarms and UPS ConditionsAlarm or Condition Possible Cause Action Troubleshooting GuideDesk for the dealer or distributor nearest you Service and SupportTroubleshooting Two-Year Limited Warranty US and Canada Chapter WarrantyWarranty Ten-Year Pro-Rated Limited Warranty US and Canada Warranty Load Protection Guarantee US and Canada Warranty Page 1642017302