Quick Start Guide
Interface Connectors
Interface Connectors
The following are the Adit 3500 interface connectors:
Note: The following is dependant upon how the system (hardware) is configured. Systems can be ordered with/without FXS, and can have from
Front of Adit
z4 DS1 Ports (used for DS1 WAN and/or PRI/CAS trunks)
-(1)
-(1) PRI/CAS group - uses 1 or 2 DS1 ports
z(1)
z(1)
z4 FXS
Back of Adit
z
zPower input connector
zBattery input connector
zGround connector
Grounding the Unit
WARNING! THE ADIT 3500 IS REQUIRED TO BE PERMANENTLY GROUNDED FOR THE PROTECTION OF USERS AND SERVICE PERSONNEL.
Chassis ground is located on the back of the unit. To ground the unit:
1.Connect a minimum 14 AWG ground wire with a #8 ring tongue terminal (not included) to the chassis ground on the back of the unit. Secure with the
Chassis Ground
2.Connect the opposite end of the ground wire to a suitable earth grounding point such as a building grounding electrode, metal water pipe, or metal building
structure that is in compliance with article 250 of NEC.
Adit 3500 - Release 1.6 | 17 |