Carrier Access Adit 3500 Setting up a CLI Connection, Set the New-line/Transmit value CR+LF

Page 24

Quick Start Guide

Setting up a CLI Connection

Setting up a CLI Connection

A CLI connection will require the LAN or WAN IP address of the unit. Note: If the WAN IP address is used, the remote admin WAN access must be enabled with the following command sequence:

Command

Description

Username: admin

Log into the system (username and password).

Password: ********

 

Adit 3500> enable

Enter the Privileged mode.

Password: ********

Enter password for the Privileged mode.

#configure terminal

Enter the Configuration mode.

(config)# remote-admin web primary-

Enable remote web admin.

port enable

 

NOTE: For Adit 3500 CLI commands see the Adit 3000 CLI Reference Manual. This is a separate document and can be found on the CD that is provided with the product, or on the Carrier Access customer website.

To connect with CLI, set up the connection:

zIf connecting via the Ethernet 100Base-TX connection, use a Telnet TCP/IP program to access the CLI. This requires an IP address of the unit.

Note: to display the current IP address of the unit, use the ifconfig command.

zIf connecting via RS-232, the port settings should be set to:

Bits per second: 115200

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None

 

zSet your Terminal Emulation to: VT100

NOTE: When using Tera Term (Telnet program) TCP/IP, CLI commands will not be recognized until the following setup is completed.

zIn Tera Term go to Setup/Terminal

zSet the New-line/Transmit value CR+LF

24

Adit 3500 - Release 1.6

Image 24
Contents Adit Page Quick Start Guide Electrostatic Discharge ESD Precautions Unpacking and InspectionInstallation Environment User SafetyInstallation Wall Mounting Rack Mounting Battery BackupCompliant Installation Ferrite Beads Ferrite beads shipped with Adit chassisSee Installation Environment on Wall MountingRack Mounting To rack mount the Adit 3000, follow the instructions belowTray Slide Battery Backup Installation#1 Adit 3500 mounted on top of the Battery Backup Attach power cords Attach Adit 3500 to the assembled BBU and brackets3500 #2 Adit 3500 and Battery Backup mounted to the wall Mount the Battery Backup to the wall with 4 #6 screws, byAdit 3500 Battery Backup Power Connector Chassis OverviewFront BackInterface Connectors Grounding the UnitFront of Adit Back of AditVAC Power Connection Battery ConnectionSpecification InputDS1/E1 Connection Ports DS1/E1 RJ-48CPin Name Description State Description10/100Base-TX Ethernet Ethernet RJ-45Reset Button RJ-11 ConnectorRS-232 Craft Port Female DB-9 Pin Direction DescriptionAlarm/Status LEDs CriticalTo access the management console Command DescriptionWeb-Based Management #show interface ethernet 2 Eth WANSetting up a CLI Connection Set the New-line/Transmit value CR+LFKey Enabled Software Features LogKey Enabled Software Features Basic Configuration Setup Adit 3500 for access via Web-BrowserRestore Factory Defaults Select Restore DefaultsModify Default Admin User Quick Start Guide Configure WAN Interface for Internet Connectivity Single T1 PPPSet the proper Framing Type and Line Coding Quick Start Guide Quick Start Guide Multiple T1s Multilink Set the proper Framing Type and Line Coding Select click New Connection to create the ML-PPP connection Enter User Name and Password Quick Start Guide Quick Start Guide Ethernet WAN Quick Start Guide Configure the Adit 3500 as a SIP Gateway On the IP Telephony tab, under Proxy Servers Select Use SIP Proxy and enter SIP Proxy IP addressQuick Start Guide Quick Start Guide Repeat this step for each FXS Line Quick Start Guide Set the Signaling Type Quick Start Guide Quick Start Guide Basic Configuration Adit 3500 Release