Bay Technical Associates 400-ST1 manual Removing a unit from the stack--- if a unit is removed

Page 11

Temporary Base Unit --- If an assigned base unit fails, the next unit in the stack order automatically becomes the new temporary base unit. This change is indicated by the Base LED on the temporary base unit’s LED display panel turning on (yellow).

The automatic base unit change to the next unit in the stack order is a temporary safeguard which allows you time to replace the failed unit, or reassign the temporary base unit as the new base unit.

Note: If you do not reassign the temporary base unit as the new base unit, and the temporary base unit fails, the automatic failover to another temporary base unit will not occur.

Set the Unit Select switch on the temporary base unit to Base (up =Base) to reassign it as the new base unit.

Removing a unit from the stack--- if a unit is removed

from the stack (therefore operating in standalone mode), the following switch configuration settings revert back to the settings configured before the unit became a member of the stack:

IP address

console password

TELNET password

SNMP community strings

9

Image 11
Contents Installing BayStack 400-ST1 Cascade Module By Bay Networks, Inc Introduction For information about Go to Contents of Shipment Front Panel Components BayStack 400-ST1 Front Panel ComponentsCascade a Out Connector Connecting Cascade Cables Base Unit Description Stack IP MAC address --- The stack IP MAC address is Removing a unit from the stack--- if a unit is removed Stack Configurations Stack Up Configuration Example Stack Down Configuration Example Page Remaining stack units remain connected Redundant Cascade Stacking FeatureRedundant Cascade Stacking Feature Installation Removing the Filler Panel Installing the 400-ST1 Cascade ModuleInstalling a 400-ST1 Cascade Module Installing and Connecting Multiple Switches Only one unit in the stack can be the base unit Installing Cascade Cables Proceed to Connecting Power on Connecting Power Verifying the Installation Apply power to the AC power stripVerifying the Installation Modifying an Existing Stack Configuration Assigning a New Base Unit to the Stack Adding Units to the Stack Add the new units to the desired location Adding Units to the End of a Stack Adding to End of Stack Removing/Replacing Units from the Stack Removing Adjacent Units Removing/Replacing Nonadjacent Units Repeat Steps 1 to 4 for unit Accessing the Firmware Images Upgrading the BayStack 450 Switch FirmwareUpgrade Restrictions Accessing the Latest Documentation