Bay Technical Associates 400-ST1 manual Removing/Replacing Nonadjacent Units

Page 36

2.Remove the cascade cable from the Cascade A In connector at unit 5.

3.Remove the units (units 3 and 4) and install replacement units as required.

4.Renumber the order of the units for the new stack configuration (if desired).

You can renumber the unit numbers as described in “Setting Up the Stack Configuration” in the Using the BayStack 450 10/100/1000 Series Switch guide.

Removing/Replacing Nonadjacent Units

Note: Remove and replace the units individually to avoid segmenting the stack configuration.

To remove/replace nonadjacent units from an operating stack, complete the following steps (see Figure 15):

1.Remove the cascade cable from the Cascade A In connector at unit 3.

2.Remove the cascade cable from the Cascade A Out connector at unit 3.

3.Remove the unit (unit 3) and install the replacement unit as required.

4.Reconnect the cascade cables (removed in Steps 1 and 2) to unit 3.

34

Image 36
Contents Installing BayStack 400-ST1 Cascade Module By Bay Networks, Inc Introduction For information about Go to Contents of Shipment BayStack 400-ST1 Front Panel Components Front Panel ComponentsCascade a Out Connector Connecting Cascade Cables Base Unit Description Stack IP MAC address --- The stack IP MAC address is Removing a unit from the stack--- if a unit is removed Stack Configurations Stack Up Configuration Example Stack Down Configuration Example Page Redundant Cascade Stacking Feature Remaining stack units remain connectedRedundant Cascade Stacking Feature Installation Installing the 400-ST1 Cascade Module Removing the Filler PanelInstalling a 400-ST1 Cascade Module Installing and Connecting Multiple Switches Only one unit in the stack can be the base unit Installing Cascade Cables Proceed to Connecting Power on Connecting Power Apply power to the AC power strip Verifying the InstallationVerifying the Installation Modifying an Existing Stack Configuration Assigning a New Base Unit to the Stack Adding Units to the Stack Add the new units to the desired location Adding Units to the End of a Stack Adding to End of Stack Removing/Replacing Units from the Stack Removing Adjacent Units Removing/Replacing Nonadjacent Units Repeat Steps 1 to 4 for unit Upgrading the BayStack 450 Switch Firmware Accessing the Firmware ImagesAccessing the Latest Documentation Upgrade Restrictions