Modifying an Existing Stack

Configuration

This section provides examples of how to modify an existing stack configuration. The examples assume the stack configuration is operational with connected stations. Always notify the attached stations that there may be a temporary disruption of the network services before you begin the modification.

To maintain the unit numbering within the stack, Bay Networks recommends that you renumber the entire stack after any modification involving configuration changes.

Note: Renumbering causes the entire stack to be reset with the current configuration settings. The Reset can take up to 30 seconds for completion. Notify the connected stations that there will be a short disruption of network services before renumbering the stack.

See the Using the BayStack 450 10/100/1000 Series Switch guide for more information about renumbering.

This section includes the following topics:

Assigning a new base unit to the stack

Adding units to the stack

Removing/replacing units from the stack

26

Image 28
Contents Installing BayStack 400-ST1 Cascade Module By Bay Networks, Inc Introduction For information about Go to Contents of Shipment BayStack 400-ST1 Front Panel Components Front Panel ComponentsCascade a Out Connector Connecting Cascade Cables Base Unit Description Stack IP MAC address --- The stack IP MAC address is Removing a unit from the stack--- if a unit is removed Stack Configurations Stack Up Configuration Example Stack Down Configuration Example Page Redundant Cascade Stacking Feature Remaining stack units remain connectedRedundant Cascade Stacking Feature Installation Installing the 400-ST1 Cascade Module Removing the Filler PanelInstalling a 400-ST1 Cascade Module Installing and Connecting Multiple Switches Only one unit in the stack can be the base unit Installing Cascade Cables Proceed to Connecting Power on Connecting Power Apply power to the AC power strip Verifying the InstallationVerifying the Installation Modifying an Existing Stack Configuration Assigning a New Base Unit to the Stack Adding Units to the Stack Add the new units to the desired location Adding Units to the End of a Stack Adding to End of Stack Removing/Replacing Units from the Stack Removing Adjacent Units Removing/Replacing Nonadjacent Units Repeat Steps 1 to 4 for unit Upgrading the BayStack 450 Switch Firmware Accessing the Firmware ImagesAccessing the Latest Documentation Upgrade Restrictions