Technics MT5634SMI-34, MT5634SMI-92 manual #Sx Enter Setup Password, #S=x Store Setup Password

Page 39

 

 

 

 

Chapter 5 – AT Commands, S-Registers, and Result Codes

Command:

#CBF?

Callback Failed Attempts Display

Values:

 

n/a

 

 

Default:

 

n/a

 

 

Description:

 

Requests the number of failed callback passwords since reset or power-up. This number

 

 

can be stored to nonvolatile memory using the &W command.

Command:

#CBFR

Callback Failed Attempts Reset

Values:

 

n/a

 

 

Default:

 

n/a

 

 

Description:

 

Resets the number of failed callback passwords to 0. This does not reset the number stored

 

 

in nonvolatile memory.

Command:

#CBIn

Local Callback Inactivity Timer

Values:

 

n = 1–255

 

Default:

 

20

 

 

Description:

 

Sets the time (in minutes) that the modem waits for a command before forcing the user to

 

 

enter the setup password again.

Command:

#CBNy=x

Store Callback Password

Values:

 

y = 0–29

 

 

 

x = password

Defaults:

 

None

 

 

Description:

 

Sets the callback security password for the y memory location. The password must have 6

 

 

to 10 characters, and cannot include the + or - characters.

Command:

#CBPn

Callback Parity

Values:

 

n = 0, 1, or 2

Default:

 

0

 

 

Description:

 

Sets parity for the callback security messages.

 

 

#CBP0

No parity.

 

 

#CBP1

Odd parity.

 

 

#CBP2

Even parity.

Command:

#CBRy

Callback Security Reset

Values:

 

y = 0–29

 

Default:

 

None

 

 

Description:

 

Clears the password and phone number in the y memory location.

Command:

#CBSn

Callback Enable/Disable

Values:

 

n = 0, 1, 2, or 3

Default:

 

0

 

 

Description:

 

#CBS0

Disables callback security.

 

 

#CBS1

Enables local and remote callback security.

 

 

#CBS2

Enables remote callback security only.

 

 

#CBS3

Disables callback security until local hangup or reset.

Command:

#Pn

Set 11-bit Parity

Values:

 

n = 0 or 1

 

Default:

 

2

 

 

Description:

 

#P0

No parity.

 

 

#P1

Odd parity.

 

 

#P2

Even parity.

Command:

#Sx

Enter Setup Password

Values:

 

x= password (1–8 characters, case sensitive)

Default:

 

MTSMODEM

Description:

 

Enters the callback security setup password.

Command:

#S=x

Store Setup Password

Values:

 

x= password (1–8 characters, case sensitive)

Default:

 

MTSMODEM

Description:

 

Stores a new callback security and remote configuration setup password.

SocketModem Global MT5634SMI Developer’s Guide

39

Image 39
Contents MT5634SMI-34 MT5634SMI-92 Revisions Table of Contents Multi-Tech’s Flash Programming Protocol Appendix C Country Configuration and Result Codes Index Product Description Specifications IntroductionProduct Description MT5634SMI Features MatrixTIA/EIA TR29.2 Technical Specifications and FeaturesStandard MT5634SMI-IT-92 Industrial Temperature 3.3V Build OptionPhysical Dimensions All Models Mechanical SpecificationsPin Configurations Pin # Signal Name I/O Type DescriptionDigital Ground Active High RDX status Tip Signal from TelcoRing Signal from Telco Active High DCD statusVCC PWR Pin # Signal Description NameDgnd GND INTElectrical Characteristics Electrical CharacteristicsTiming Requirements for Parallel Read Handling PrecautionsTiming Requirements Timing Requirements for Parallel WriteSocketModem Parallel Interface a Programmer’s Description SocketModem Parallel Interface Internal RegistersSocketModem Mimic MMM Operation Register Name Register Description Host Access Special Register Set Note *2 Time Out InterruptsRegister Functional Descriptions Internal RegistersTHR Transmit Holding Register TX Fifo IER Interrupt EnableBit Priority Interrupt Source Interrupt Reset Control RBR Receive Buffer RX FifoFCR Fifo Control LCR Line ControlMCR Modem Control MSR Modem Status LSR Line StatusBaud Rate Clock Divisor Decimal DLM Value HEX DLL Value HEX SCR ScratchDLL Divisor Latch LSByte DLM Divisor Latch MSByteAT Command Summary AT Commands, S-Registers Result CodesSet Register Value Modulation HandshakeDS= y Dial Stored Telephone Number AT CommandsEnter Key Dial string modifiersReturn Online to Data Mode Sr? Sr= n Set Register ValueXON/XOFF Pacing Control Zy=x Store Dialing Command \An Select Maximum MNP Block Size\Bn Transmit Break Data mode. The modem receives the break from the computer \Nn Error Correction Mode Selection\Tn Inactivity Timer \Kn Break Control\Xn XON/XOFF Pass-Through DCn AT Command Control$MBn Online BPS Speed $RPn Ring Priority vs. AT Command Priority$Dn DTR Dialing $EBn Asynchronous Word Length#CBNy=x Store Callback Password #CBDn Callback DelayCallback Failed Attempts Reset #CBIn Local Callback Inactivity TimerEscape AT Commands Modulation Possible rates bps1 Commands+MS= Modulation Selection Subparameters+PIG=n PCM Upstream Ignore +PCW=n Call Waiting Enable+PMH=n Modem on Hold Enable Mod value Valid maxrate values bps+PMHT=n Modem on Hold Timer +PMHF V.92 Modem Hook Flash+PMHR=n Modem on Hold Initiate +VCID=n Caller ID Selection +PQC=n Quick Connect Control#S=x Store Setup Password #Sx Enter Setup PasswordRegisters Register Unit Range Default DescriptionS48=7 S48=128 S38Terse Verbose Description Result Codes111 Voice Commands Voice Commands Commands That Change for Voice Mode SupportVoice S-Register Summary +FCLASS= mode Enter Select Modem Operating Mode Voice +V Commands SummaryVoice +V Commands Detail Command DescriptionTouch Tone Signals Digit Low frequency High frequency AT+FCLASS=? Enter Display Service Class Capabilities+FCLASS=8 Dtmf Detect Detect and Control Dtmf +FMR?Enter Report Version Level +VNH=hookEnter Automatic Hang-Up Control+FMI?Enter Report Manufacturers ID +FMM?Enter Report Product IDEnter Voice Receive State +VTS=string Produce Dtmf and Tone Generation in Voice Mode+VGR=gain Set the Gain for Received Voice Samples +VTS=? Report Frequency SupportAT+VTS=? Start Voice Transmission ProcessCode Description +VGT=level Set the Volume for Transmitted Voice Samples+VIT=timer Set DTE/DCE Inactivity Timer +VLS=label Select Analog Source/Destination+VRA=interval Set Ring Back Goes Away Timer +VRN=interval Set Ring Back Never Appeared Timer +VSD=sds,sdi Set Silence Detection Sensitivity+VSM=cml,vsr,scs,sel Select Voice Compression Method +VSM=? Report Voice Compression Method AT+VSM=?Identifier Description Enable Report Description +VDT=enable,report Control Tone Cadence ReportingLsltcq +VEM=? Report Event Reporting and Masking Capabilities +VEM=mask Event Reporting and MaskingAT+VBT=? Interface Configuration Commands+VPP=enable Enable or Disable Voice Mode Packet Protocol +VBT=? Report Modem Flow Control Assert and Deassert PointsVoice Mode Result Codes Flow Control+VPR=rate Select DTE/DCE Interface Rate Turn Off Autobaud Unsolicited Voice Mode Result Codes Valid Complex Event Report TagsTag Description Shielded Code Hex Event Report Description Voice Mode Shielded CodesAscii Command Response Sample SessionsSample Rate Selection and Suggested Compression Method AT+VLS=0 AT+VLS=4AT+VTX DLE ETXAT+VNH=1 AT+VLS=2AT+VRX DLE NULDTE/DCE Interface Rates Related ManualsAdditional Information Fax Commands Setup Remote Configuration Country Code ConfigurationRemote Configuration Basic ProcedureCountry AT Command Result Code Hexadecimal Decimal Country Code ConfigurationUsing the Global Wizard Utility Using AT CommandsFirmware Upgrade Procedure Upgrade OverviewUpgrade Steps Identify the Current Version of the Firmware Download the Upgrade FileInstall the Flash Wizard Extract the Firmware Upgrade .Hex FilesUpgrade the Modem’s Firmware Using the Flash WizardRestore Your Parameters Handshake Sequence Multi-Tech Systems, Inc. Flash Programming ProtocolProgramming the Modem Modem CommentsOther Supported Boot Code Commands Other Programming ConcernsATI4 End of File Record Char Pos Field Type Value Description Intel Hex FormatData Record Char Pos Field Type Value Description Example Extended Address Record in Intel FormatExample End of File in Intel Format Serial Test/Demo Board Components Appendix a Mechanical Details5V / 3.3V Jumper JP1 Serial Test/Demo Board Block DiagramParallel Test/Demo Board Components Address/COM Port/ IRQ Select Jumpers JP2 and JP3Operating Voltage Select Jumper JP4 Figure A-4. Parallel Test/Demo Board Block Diagram Parallel Test/Demo Board Block DiagramTelecom Approvals Safety and EMC ApprovalsHardware Considerations Regulatory Design ConsiderationsSafety 5V Tolerant Inputs for 3.3V Modules Industry Canada FCC Part 15 RegulationTelecom Labeling Requirements FCC Part 68 TelecomReregistration From FCC Part 68 Subpart D Conditions for RegistrationCanadian Limitations Notice Fax Branding StatementMultiple Listing EMC, Safety, and R&TTE Directive ComplianceIndustry Canada CS-03 International Modem RestrictionsSouth African Notice New Zealand Telecom Warning NoticeCountry Country Config. hex ATI9 Response Appendix C Country Configuration Result CodesAppendix C Country Configuration and Result Codes Appendix C Country Configuration and Result Codes Appendix C Country Configuration and Result Codes Page Index Index Index Index