Appendix B – Product Approvals, Design Considerations, Regulatory Information

FCC Part 15 Regulation

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

￿Reorient or relocate the receiving antenna.

￿Increase the separation between the equipment and receiver.

￿Plug the equipment into an outlet on a circuit different from that to which the receiver is connected.

￿Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC rules. Operation of this device is subject to the following conditions:

(1)This device may not cause harmful interference, and (2) this device must accept any interference that may cause undesired operation.

WARNING – Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Industry Canada

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil numérique de la classe B respecte toutes les exigences du Reglement Canadien sur le matériel brouilleur.

SocketModem Global MT5634SMI Developer’s Guide

84

Image 84
Contents MT5634SMI-34 MT5634SMI-92 Revisions Table of Contents Multi-Tech’s Flash Programming Protocol Appendix C Country Configuration and Result Codes Index Product Description Specifications IntroductionProduct Description Features Matrix MT5634SMITechnical Specifications and Features TIA/EIA TR29.2MT5634SMI-IT-92 Industrial Temperature 3.3V Build Option StandardMechanical Specifications Physical Dimensions All ModelsPin Configurations Pin # Signal Name I/O Type DescriptionDigital Ground Tip Signal from Telco Ring Signal from TelcoActive High DCD status Active High RDX statusPin # Signal Description Name Dgnd GNDINT VCC PWRElectrical Characteristics Electrical CharacteristicsHandling Precautions Timing RequirementsTiming Requirements for Parallel Write Timing Requirements for Parallel ReadSocketModem Parallel Interface a Programmer’s Description SocketModem Parallel Interface Internal RegistersSocketModem Mimic MMM Operation Register Name Register Description Host Access Time Out Interrupts Register Functional DescriptionsInternal Registers Special Register Set Note *2IER Interrupt Enable Bit Priority Interrupt Source Interrupt Reset ControlRBR Receive Buffer RX Fifo THR Transmit Holding Register TX FifoFCR Fifo Control LCR Line ControlMCR Modem Control LSR Line Status MSR Modem StatusSCR Scratch DLL Divisor Latch LSByteDLM Divisor Latch MSByte Baud Rate Clock Divisor Decimal DLM Value HEX DLL Value HEXAT Commands, S-Registers Result Codes AT Command SummaryModulation Handshake Set Register ValueAT Commands Enter KeyDial string modifiers DS= y Dial Stored Telephone NumberReturn Online to Data Mode Sr= n Set Register Value Sr?XON/XOFF Pacing Control Zy=x Store Dialing Command \An Select Maximum MNP Block Size\Bn Transmit Break \Nn Error Correction Mode Selection \Tn Inactivity Timer\Kn Break Control Data mode. The modem receives the break from the computerDCn AT Command Control \Xn XON/XOFF Pass-Through$RPn Ring Priority vs. AT Command Priority $Dn DTR Dialing$EBn Asynchronous Word Length $MBn Online BPS Speed#CBDn Callback Delay Callback Failed Attempts Reset#CBIn Local Callback Inactivity Timer #CBNy=x Store Callback PasswordEscape AT Commands Commands +MS= Modulation SelectionSubparameters Modulation Possible rates bps1+PCW=n Call Waiting Enable +PMH=n Modem on Hold EnableMod value Valid maxrate values bps +PIG=n PCM Upstream Ignore+PMHT=n Modem on Hold Timer +PMHF V.92 Modem Hook Flash+PMHR=n Modem on Hold Initiate +PQC=n Quick Connect Control +VCID=n Caller ID Selection#Sx Enter Setup Password #S=x Store Setup PasswordRegister Unit Range Default Description RegistersS38 S48=7 S48=128Result Codes Terse Verbose Description111 Voice Commands Voice Commands Commands That Change for Voice Mode SupportVoice S-Register Summary Voice +V Commands Summary Voice +V Commands DetailCommand Description +FCLASS= mode Enter Select Modem Operating ModeTouch Tone Signals Digit Low frequency High frequency AT+FCLASS=? Enter Display Service Class Capabilities+FCLASS=8 Dtmf Detect Detect and Control Dtmf +VNH=hookEnter Automatic Hang-Up Control +FMI?Enter Report Manufacturers ID+FMM?Enter Report Product ID +FMR?Enter Report Version Level+VTS=string Produce Dtmf and Tone Generation in Voice Mode Enter Voice Receive State+VTS=? Report Frequency Support AT+VTS=?Start Voice Transmission Process +VGR=gain Set the Gain for Received Voice Samples+VGT=level Set the Volume for Transmitted Voice Samples +VIT=timer Set DTE/DCE Inactivity Timer+VLS=label Select Analog Source/Destination Code Description+VRA=interval Set Ring Back Goes Away Timer +VRN=interval Set Ring Back Never Appeared Timer +VSD=sds,sdi Set Silence Detection Sensitivity+VSM=cml,vsr,scs,sel Select Voice Compression Method +VSM=? Report Voice Compression Method AT+VSM=?Identifier Description Enable Report Description +VDT=enable,report Control Tone Cadence ReportingLsltcq +VEM=mask Event Reporting and Masking +VEM=? Report Event Reporting and Masking CapabilitiesInterface Configuration Commands +VPP=enable Enable or Disable Voice Mode Packet Protocol+VBT=? Report Modem Flow Control Assert and Deassert Points AT+VBT=?Voice Mode Result Codes Flow Control+VPR=rate Select DTE/DCE Interface Rate Turn Off Autobaud Unsolicited Voice Mode Result Codes Valid Complex Event Report TagsTag Description Voice Mode Shielded Codes Shielded Code Hex Event Report DescriptionAscii Command Response Sample SessionsSample Rate Selection and Suggested Compression Method AT+VLS=4 AT+VTXDLE ETX AT+VLS=0AT+VLS=2 AT+VRXDLE NUL AT+VNH=1DTE/DCE Interface Rates Related ManualsAdditional Information Fax Commands Remote Configuration Country Code Configuration Remote ConfigurationBasic Procedure SetupCountry Code Configuration Using the Global Wizard UtilityUsing AT Commands Country AT Command Result Code Hexadecimal DecimalFirmware Upgrade Procedure Upgrade OverviewUpgrade Steps Download the Upgrade File Install the Flash WizardExtract the Firmware Upgrade .Hex Files Identify the Current Version of the FirmwareUpgrade the Modem’s Firmware Using the Flash WizardRestore Your Parameters Multi-Tech Systems, Inc. Flash Programming Protocol Programming the ModemModem Comments Handshake SequenceOther Supported Boot Code Commands Other Programming ConcernsATI4 Intel Hex Format Data Record Char Pos Field Type Value DescriptionExample Extended Address Record in Intel Format End of File Record Char Pos Field Type Value DescriptionExample End of File in Intel Format Appendix a Mechanical Details Serial Test/Demo Board ComponentsSerial Test/Demo Board Block Diagram 5V / 3.3V Jumper JP1Parallel Test/Demo Board Components Address/COM Port/ IRQ Select Jumpers JP2 and JP3Operating Voltage Select Jumper JP4 Parallel Test/Demo Board Block Diagram Figure A-4. Parallel Test/Demo Board Block DiagramSafety and EMC Approvals Telecom Approvals Regulatory Design Considerations Hardware ConsiderationsSafety 5V Tolerant Inputs for 3.3V Modules FCC Part 15 Regulation Industry CanadaFCC Part 68 Telecom Telecom Labeling RequirementsFrom FCC Part 68 Subpart D Conditions for Registration ReregistrationFax Branding Statement Canadian Limitations NoticeEMC, Safety, and R&TTE Directive Compliance Industry Canada CS-03International Modem Restrictions Multiple ListingNew Zealand Telecom Warning Notice South African NoticeAppendix C Country Configuration Result Codes Country Country Config. hex ATI9 ResponseAppendix C Country Configuration and Result Codes Appendix C Country Configuration and Result Codes Appendix C Country Configuration and Result Codes Page Index Index Index Index