Technics MT5634SMI-34, MT5634SMI-92 manual Fax Branding Statement, Canadian Limitations Notice

Page 87

Appendix B – Product Approvals, Design Considerations, Regulatory Information

Fax Branding Statement

The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device, including fax machines, to send any message unless such message clearly contains the following information:

￿Date and time the message is sent

￿Identification of the business or other entity, or other individual sending the message

￿Telephone number of the sending machine or such business, other entity, or individual

This information is to appear in a margin at the top or bottom of each transmitted page or on the first page of the transmission. (Adding this information in the margin is referred to as fax branding.)

Since any number of fax software packages can be used with this product, the user must refer to the fax software manual for setup details. Typically the fax branding information must be entered via the configuration menu of the software.

Canadian Limitations Notice

Notice: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5.

Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Industry Canada label does not guarantee the equipment will operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

SocketModem Global MT5634SMI Developer’s Guide

87

Image 87
Contents MT5634SMI-34 MT5634SMI-92 Revisions Table of Contents Multi-Tech’s Flash Programming Protocol Appendix C Country Configuration and Result Codes Index Product Description Specifications IntroductionProduct Description MT5634SMI Features MatrixTIA/EIA TR29.2 Technical Specifications and FeaturesStandard MT5634SMI-IT-92 Industrial Temperature 3.3V Build OptionPhysical Dimensions All Models Mechanical SpecificationsPin Configurations Pin # Signal Name I/O Type DescriptionDigital Ground Active High RDX status Tip Signal from TelcoRing Signal from Telco Active High DCD statusVCC PWR Pin # Signal Description NameDgnd GND INTElectrical Characteristics Electrical CharacteristicsTiming Requirements for Parallel Read Handling PrecautionsTiming Requirements Timing Requirements for Parallel WriteSocketModem Parallel Interface a Programmer’s Description SocketModem Parallel Interface Internal RegistersSocketModem Mimic MMM Operation Register Name Register Description Host Access Special Register Set Note *2 Time Out InterruptsRegister Functional Descriptions Internal RegistersTHR Transmit Holding Register TX Fifo IER Interrupt EnableBit Priority Interrupt Source Interrupt Reset Control RBR Receive Buffer RX FifoFCR Fifo Control LCR Line ControlMCR Modem Control MSR Modem Status LSR Line StatusBaud Rate Clock Divisor Decimal DLM Value HEX DLL Value HEX SCR ScratchDLL Divisor Latch LSByte DLM Divisor Latch MSByteAT Command Summary AT Commands, S-Registers Result CodesSet Register Value Modulation HandshakeDS= y Dial Stored Telephone Number AT CommandsEnter Key Dial string modifiersReturn Online to Data Mode Sr? Sr= n Set Register ValueXON/XOFF Pacing Control Zy=x Store Dialing Command \An Select Maximum MNP Block Size\Bn Transmit Break Data mode. The modem receives the break from the computer \Nn Error Correction Mode Selection\Tn Inactivity Timer \Kn Break Control\Xn XON/XOFF Pass-Through DCn AT Command Control$MBn Online BPS Speed $RPn Ring Priority vs. AT Command Priority$Dn DTR Dialing $EBn Asynchronous Word Length#CBNy=x Store Callback Password #CBDn Callback DelayCallback Failed Attempts Reset #CBIn Local Callback Inactivity TimerEscape AT Commands Modulation Possible rates bps1 Commands+MS= Modulation Selection Subparameters+PIG=n PCM Upstream Ignore +PCW=n Call Waiting Enable+PMH=n Modem on Hold Enable Mod value Valid maxrate values bps+PMHT=n Modem on Hold Timer +PMHF V.92 Modem Hook Flash+PMHR=n Modem on Hold Initiate +VCID=n Caller ID Selection +PQC=n Quick Connect Control#S=x Store Setup Password #Sx Enter Setup PasswordRegisters Register Unit Range Default DescriptionS48=7 S48=128 S38Terse Verbose Description Result Codes111 Voice Commands Voice Commands Commands That Change for Voice Mode SupportVoice S-Register Summary +FCLASS= mode Enter Select Modem Operating Mode Voice +V Commands SummaryVoice +V Commands Detail Command DescriptionTouch Tone Signals Digit Low frequency High frequency AT+FCLASS=? Enter Display Service Class Capabilities+FCLASS=8 Dtmf Detect Detect and Control Dtmf +FMR?Enter Report Version Level +VNH=hookEnter Automatic Hang-Up Control+FMI?Enter Report Manufacturers ID +FMM?Enter Report Product IDEnter Voice Receive State +VTS=string Produce Dtmf and Tone Generation in Voice Mode+VGR=gain Set the Gain for Received Voice Samples +VTS=? Report Frequency SupportAT+VTS=? Start Voice Transmission ProcessCode Description +VGT=level Set the Volume for Transmitted Voice Samples+VIT=timer Set DTE/DCE Inactivity Timer +VLS=label Select Analog Source/Destination+VRA=interval Set Ring Back Goes Away Timer +VRN=interval Set Ring Back Never Appeared Timer +VSD=sds,sdi Set Silence Detection Sensitivity+VSM=cml,vsr,scs,sel Select Voice Compression Method +VSM=? Report Voice Compression Method AT+VSM=?Identifier Description Enable Report Description +VDT=enable,report Control Tone Cadence ReportingLsltcq +VEM=? Report Event Reporting and Masking Capabilities +VEM=mask Event Reporting and MaskingAT+VBT=? Interface Configuration Commands+VPP=enable Enable or Disable Voice Mode Packet Protocol +VBT=? Report Modem Flow Control Assert and Deassert PointsVoice Mode Result Codes Flow Control+VPR=rate Select DTE/DCE Interface Rate Turn Off Autobaud Unsolicited Voice Mode Result Codes Valid Complex Event Report TagsTag Description Shielded Code Hex Event Report Description Voice Mode Shielded CodesAscii Command Response Sample SessionsSample Rate Selection and Suggested Compression Method AT+VLS=0 AT+VLS=4AT+VTX DLE ETXAT+VNH=1 AT+VLS=2AT+VRX DLE NULDTE/DCE Interface Rates Related ManualsAdditional Information Fax Commands Setup Remote Configuration Country Code ConfigurationRemote Configuration Basic ProcedureCountry AT Command Result Code Hexadecimal Decimal Country Code ConfigurationUsing the Global Wizard Utility Using AT CommandsFirmware Upgrade Procedure Upgrade OverviewUpgrade Steps Identify the Current Version of the Firmware Download the Upgrade FileInstall the Flash Wizard Extract the Firmware Upgrade .Hex FilesUpgrade the Modem’s Firmware Using the Flash WizardRestore Your Parameters Handshake Sequence Multi-Tech Systems, Inc. Flash Programming ProtocolProgramming the Modem Modem CommentsOther Supported Boot Code Commands Other Programming ConcernsATI4 End of File Record Char Pos Field Type Value Description Intel Hex FormatData Record Char Pos Field Type Value Description Example Extended Address Record in Intel FormatExample End of File in Intel Format Serial Test/Demo Board Components Appendix a Mechanical Details5V / 3.3V Jumper JP1 Serial Test/Demo Board Block DiagramParallel Test/Demo Board Components Address/COM Port/ IRQ Select Jumpers JP2 and JP3Operating Voltage Select Jumper JP4 Figure A-4. Parallel Test/Demo Board Block Diagram Parallel Test/Demo Board Block DiagramTelecom Approvals Safety and EMC ApprovalsHardware Considerations Regulatory Design ConsiderationsSafety 5V Tolerant Inputs for 3.3V Modules Industry Canada FCC Part 15 RegulationTelecom Labeling Requirements FCC Part 68 TelecomReregistration From FCC Part 68 Subpart D Conditions for RegistrationCanadian Limitations Notice Fax Branding StatementMultiple Listing EMC, Safety, and R&TTE Directive ComplianceIndustry Canada CS-03 International Modem RestrictionsSouth African Notice New Zealand Telecom Warning NoticeCountry Country Config. hex ATI9 Response Appendix C Country Configuration Result CodesAppendix C Country Configuration and Result Codes Appendix C Country Configuration and Result Codes Appendix C Country Configuration and Result Codes Page Index Index Index Index