Chapter 3 OperationIPmux-16Installation and Operation Manual
Table 3-1. IPmux-16 System Indicators and Switches
No | Module | Name | Type | Function |
|
|
|
|
|
1 | System | RDY | LED | On: Device OK |
|
|
|
| OFF: |
|
|
|
| Blinking: Malfunction detected |
|
|
|
|
|
2 | System | PS1/PS2 | LED | On: Unit powered |
|
|
|
| Off: Unit not powered |
|
|
|
|
|
3 | System | ALM | LED | Red: Alarm |
|
|
|
| Off: No alarm |
|
|
|
|
|
4 | Ethernet | LINK | LED | Off: Link not active |
|
|
|
| On: Line OK |
|
|
|
|
|
5 | Ethernet | ACT | LED | Off: No activity |
|
|
|
| On: Frame being transferred on line |
|
|
|
|
|
6 | Ethernet | 100M | LED | Off: 10 MHz |
|
|
|
| On: 100 MHz |
|
|
|
|
|
7 | Ethernet | FDX | LED | Off: Half duplex |
|
|
|
| On: Full duplex |
|
|
|
|
|
8 | E1 | SYNC | LED | On: Port synchronized (no alarm) |
|
|
|
| Off: Unframed - Signal loss or AIS |
|
|
|
| detected |
|
|
|
| Framed - Signal loss, loss of frame or |
|
|
|
| AIS detected |
|
|
|
| Blinking: RDI detected (remote alarm) |
|
|
|
|
|
9 | Rear panel | PS1/PS2 | Switch | Turns |
|
|
|
|
|
3.3 Operating Instructions
Turning IPmux-16 On – Without Control Terminal
➤To power up IPmux-16 without a terminal:
•Switch the PS1 power supply switch, located on the rear panel, to ON.
After