Table
Message | Causes | Corrective Actions |
|
|
|
Memory address line | Faulty or improperly installed memory | See "Troubleshooting System Memory" |
failure at address, read | modules. | on page 120. |
value expecting value |
|
|
Memory double word logic |
|
|
failure at address, read |
|
|
value expecting value |
|
|
Memory odd/even logic |
|
|
failure at address, read |
|
|
value expecting value |
|
|
Memory write/read failure |
|
|
at address, read value |
|
|
expecting value |
|
|
|
|
|
Memory tests terminated by | POST memory test terminated by | Information only. |
keystroke. | pressing the spacebar. |
|
No boot device available | Faulty or missing optical/diskette |
| drive subsystem, hard drive, or hard- |
| drive subsystem, or no boot disk in |
| drive A. |
Use a bootable diskette, CD, or hard drive. If the problem persists, see "Troubleshooting a Diskette Drive" on page 121, "Troubleshooting an Optical Drive" on page 123, and "Troubleshooting a Hard Drive" on page 124. See "Using the System Setup Program" on page 37 for information on setting the order of boot devices.
No boot sector on hard drive
Incorrect configuration settings in System Setup program, or no operating system on hard drive.
Check the
No timer tick interrupt | Faulty system board. | See “"Getting Help" on page 147." |
|
|
|
Northbound merge error - | The specified DIMM was unable to | See "Troubleshooting System Memory" |
The following DIMM has | establish a successful data link with | on page 120. |
been disabled by BIOS: | the memory controller. |
|
DIMM x |
|
|
|
|
|
Not a boot diskette | No operating system on diskette. | Use a bootable diskette. |