Nx Networks NX series user manual Installation 2186, NX dimensions, IP21 with collar, FR4 to FR6

Page 21

5

Installation

21(86)

W2

 

H4

 

 

D1

 

H5

D2

 

H1 H2

 

W1

H3

 

Ø

 

 

fr5ip21kaulus.fh8

Figure 5-2. NX dimensions, IP21 with collar, FR4 to FR6

Type

 

 

 

 

Dimensions

 

 

 

 

 

W1

W2

H1

H2

 

H3

H4

H5

D1

D2

 

 

 

 

 

 

 

 

 

 

 

 

0004—0015 NX_2

 

 

 

 

 

 

 

 

 

 

 

0003—0012 NX_5

128

113

337

325

327

30

22

190

77

7

0005—0019 NX_6

 

 

 

 

 

 

 

 

 

 

 

0018—0032 NX_2

 

 

 

 

 

 

 

 

 

 

 

0016—0031 NX_5

144

120

434

420

419

36

18

214

100

7

0022—0035 NX_6

 

 

 

 

 

 

 

 

 

 

 

0048—0092 NX_2

 

 

 

 

 

 

 

 

 

 

 

0038—0061 NX_5

195

170

560

549

558

30

20

237

106

6.5

0042—0085 NX_6

 

 

 

 

 

 

 

 

 

 

 

Table 5-2. Dimensions for different frequency converter types FR4 to FR6, IP21 with collar

Image 21
Contents NX series Start-up Quick Guide Contents NX USER’S Manual Application Manual 486Index 586Control Keypad 686Safety Safety instructions786 Earthing and earth fault protection Running the motor= Dangerous voltage = General warning General Technical criteriaNX frequency converter EMC classification Class T 1086Class N Manufacturers declaration of conformity1186 EU Declaration of ConformityReceipt of shipment 1286Type designation code StorageMaintenance Warranty1386 Technical data 1486Introduction 1586 Power ratings 16861 NX5 Mains voltage 380-500 Characteristrics 17861886 Technical dataInstallation 1986Mounting NX dimensions, IP21 2086 InstallationNX dimensions, IP21 with collar, FR4 to FR6 Installation 2186Opening needed for the collar installation, FR4 to FR6 2286 InstallationNX dimensions, IP21 with collar, FR7 and FR8 Installation 2386Opening needed for the collar installation, FR7/FR8 2486 InstallationCooling 2586Power loss Power loss as function of switching frequency2686 2786 Power loss as function of switching frequency 0038…0061NX5Power unit 2886Cabling and connections 2986 External RFI-filter Filter OptionMains cable Power connectionsMotor cable Control cableCable and fuse sizes 31863286 Installation instructions3386 Stripping lengths of motor and mains cables 34863586 NX frequency converter frames and installation of cablesNX, FR5. Protection class IP21 3686NX, FR6. Protection class IP21 378610. NX, FR7. Protection class IP21 3886Cable installation and the UL standards 3986Cable and motor insulation checks 4086 Control unitControl connections 4186 NXOPTA1Galvanic isolation barriers Control cables4386 Control terminal signals4486 Digital input signal inversions+24V Ground +24V4586 Jumper block AI1 mode AI2 modeControl keypad 4686Indications on the Keypad display Drive status indications See control keypad4786 See .3.4, Active FaultsControl place indications See control keypad Status LEDs green green red See control keypad4886 Keypad push-buttons ResetButton descriptions SelectNavigation on the control keypad 5186 No editingMonitoring menu M1 5286Parameter menu M2 53865486 P1 P18 Select the keypad as the active control place by keeping Keypad control menu M3Selection of control place Control placeKeypad direction Keypad referenceActive faults menu M4 Fault types5886 5986 Fault type symbol Meaning6086 Fault codes6186 Fault code Possible cause Correcting measures6286 Fault time data record6386 Fault history menu M5System menu M6 6486Functions in the System menu 65866686 Code Function Min Max Unit Default Cust Selections6786 Application selectionLanguage selection 6886 System settings6986 ChangeEnable ChangeDisabl7086 Connected Not connKeypad settings 7186Example 7286 Keypad settings DefaultParameter copy 738620. Storing and loading of parameter sets 7486Parameter comparison 7586Information submenu 7686Counters menu 7786Trip counters submenu 7886Expander board menu M7 7986G1 G2 AutoFurther keypad functions 8086Commissioning 8186Commissioning of the frequency converter 8286 8386 8486 Fault tracing8586 Bulgaria