The control keypad is the link between the frequency converter and the user. The NX control

keypad features an alphanumeric display with seven indicators for the Run status (RUN, , READY, STOP, ALARM, FAULT) and three indicators for the control place (I/O term/ Keypad/BusComm). There are also three Status Indicator LEDs (green - green - red), see Status LEDs (green – green – red) below.

The control information, i.e. the number of menu, description of menu or the displayed value and the numeric information are presented on three text lines.

The frequency converter is operable through the nine push-buttons of the control keypad. Furthermore, the buttons serve the purposes of parameter setting and value monitoring.

The keypad is detachable and isolated from the input line potential.

7.1 Indications on the Keypad display

••

•••

1

2

3

4

5

6

RUNSTOPREADYALARMFAULT

I/O term Keypad

Bus/Comm

a

b

c

ready

run

fault

 

I II III

Figure 7-1. The control keypad and drive status indications

7.1.1Drive status indications (See control keypad)

The drive status indications tell the user what the status of the motor and the drive is, and whether the motor control software has detected irregularities in motor or frequency converter functions.

1

RUN

=

Motor is running; Blinks when the stop command has been given but the frequency is

 

 

 

 

 

 

 

still ramping down.

2

 

 

 

 

 

= Indicates the direction of motor rotation.

 

 

 

 

 

3

STOP

=

Indicates that the drive is not running.

Image 46
Contents NX series Start-up Quick Guide Contents NX USER’S Manual 486 Application Manual586 Index686 Control KeypadSafety instructions Safety786 Running the motor Earthing and earth fault protection= Dangerous voltage = General warning Technical criteria GeneralNX frequency converter EMC classification Class N 1086Class T Manufacturers declaration of conformityEU Declaration of Conformity 1186Type designation code 1286Receipt of shipment StorageWarranty Maintenance1386 1486 Technical dataIntroduction 1586 1686 Power ratings1 NX5 Mains voltage 380-500 1786 CharacteristricsTechnical data 18861986 InstallationMounting 2086 Installation NX dimensions, IP21Installation 2186 NX dimensions, IP21 with collar, FR4 to FR62286 Installation Opening needed for the collar installation, FR4 to FR6Installation 2386 NX dimensions, IP21 with collar, FR7 and FR82486 Installation Opening needed for the collar installation, FR7/FR82586 CoolingPower loss as function of switching frequency Power loss2686 Power loss as function of switching frequency 0038…0061NX5 27862886 Power unitCabling and connections External RFI-filter Filter Option 2986Motor cable Power connectionsMains cable Control cable3186 Cable and fuse sizesInstallation instructions 32863386 3486 Stripping lengths of motor and mains cablesNX frequency converter frames and installation of cables 35863686 NX, FR5. Protection class IP213786 NX, FR6. Protection class IP213886 10. NX, FR7. Protection class IP213986 Cable installation and the UL standardsCable and motor insulation checks Control unit 4086Control connections NXOPTA1 4186Control cables Galvanic isolation barriersControl terminal signals 4386+24V Ground Digital input signal inversions4486 +24VJumper block AI1 mode AI2 mode 4586Indications on the Keypad display 4686Control keypad Drive status indications See control keypadControl place indications See control keypad See .3.4, Active Faults4786 Status LEDs green green red See control keypad4886 Button descriptions ResetKeypad push-buttons SelectNavigation on the control keypad No editing 51865286 Monitoring menu M15386 Parameter menu M25486 P1 P18 Selection of control place Keypad control menu M3Select the keypad as the active control place by keeping Control placeKeypad reference Keypad directionFault types Active faults menu M45886 Fault type symbol Meaning 5986Fault codes 6086Fault code Possible cause Correcting measures 6186Fault time data record 6286Fault history menu M5 63866486 System menu M66586 Functions in the System menuCode Function Min Max Unit Default Cust Selections 6686Application selection 6786Language selection System settings 6886ChangeEnable ChangeDisabl 6986Connected Not conn 70867186 Keypad settingsExample Keypad settings Default 72867386 Parameter copy7486 20. Storing and loading of parameter sets7586 Parameter comparison7686 Information submenu7786 Counters menu7886 Trip counters submenuG1 G2 7986Expander board menu M7 Auto8086 Further keypad functions8186 CommissioningCommissioning of the frequency converter 8286 8386 Fault tracing 84868586 Bulgaria