Nx Networks NX series user manual Navigation on the control keypad

Page 50

7

50(86)

 

Control keypad

start

=

Start button.

 

 

Pressing this button starts the motor if the keypad is the active control

 

 

place. See Chapter 7.3.3.1.

stop

=

Stop button.

 

Pressing this button stops the motor (unless disabled by parameter

 

 

 

 

R3.4/R3.6).

7.3 Navigation on the control keypad

The data on the control keypad are arranged in menus and submenus. The menus are used for example for the display and editing of measurement and control signals, parameter settings (chapter 7.3.2), reference values and fault displays (chapter 7.3.4). Through the menus, the contrast of the display (page 73) can be adjusted.

Location

Description

Number of items available; Item value

STOP READY

Local

Monitor

V1"V14

The first menu level consists of menus M1 to M7 and is called the Main menu. The user can navigate in the main menu using the Browser buttons up and down. The desired submenu can be entered from the main menu using the Menu buttons. When there still are pages to enter under the currently displayed menu or page, an arrow () can be seen in the lower right corner of the display and by pressing the right arrow menu button, the next menu level can be reached.

The control keypad navigation chart is shown on the next page. Please note that the menu M1 is located in the lower left corner. From there it is possible to navigate your way up to the desired menu using the menu and browser buttons.

More detailed descriptions of the menus can be found later in this Chapter.

Image 50
Contents NX series Start-up Quick Guide Contents NX USER’S Manual 486 Application Manual586 Index686 Control Keypad786 SafetySafety instructions = Dangerous voltage = General warning Earthing and earth fault protectionRunning the motor NX frequency converter EMC classification GeneralTechnical criteria Class N 1086Class T Manufacturers declaration of conformityEU Declaration of Conformity 1186Type designation code 1286Receipt of shipment Storage1386 MaintenanceWarranty Introduction Technical data1486 1586 1 NX5 Mains voltage 380-500 Power ratings1686 1786 CharacteristricsTechnical data 1886Mounting Installation1986 2086 Installation NX dimensions, IP21Installation 2186 NX dimensions, IP21 with collar, FR4 to FR62286 Installation Opening needed for the collar installation, FR4 to FR6Installation 2386 NX dimensions, IP21 with collar, FR7 and FR82486 Installation Opening needed for the collar installation, FR7/FR82586 Cooling2686 Power lossPower loss as function of switching frequency Power loss as function of switching frequency 0038…0061NX5 2786Cabling and connections Power unit2886 External RFI-filter Filter Option 2986Motor cable Power connectionsMains cable Control cable3186 Cable and fuse sizesInstallation instructions 32863386 3486 Stripping lengths of motor and mains cablesNX frequency converter frames and installation of cables 35863686 NX, FR5. Protection class IP213786 NX, FR6. Protection class IP213886 10. NX, FR7. Protection class IP21Cable and motor insulation checks Cable installation and the UL standards3986 Control connections 4086Control unit NXOPTA1 4186Control cables Galvanic isolation barriersControl terminal signals 4386+24V Ground Digital input signal inversions4486 +24VJumper block AI1 mode AI2 mode 4586Indications on the Keypad display 4686Control keypad Drive status indications See control keypadControl place indications See control keypad See .3.4, Active Faults4786 Status LEDs green green red See control keypad4886 Button descriptions ResetKeypad push-buttons SelectNavigation on the control keypad No editing 51865286 Monitoring menu M15386 Parameter menu M25486 P1 P18 Selection of control place Keypad control menu M3Select the keypad as the active control place by keeping Control placeKeypad reference Keypad direction5886 Active faults menu M4Fault types Fault type symbol Meaning 5986Fault codes 6086Fault code Possible cause Correcting measures 6186Fault time data record 6286Fault history menu M5 63866486 System menu M66586 Functions in the System menuCode Function Min Max Unit Default Cust Selections 6686Language selection 6786Application selection System settings 6886ChangeEnable ChangeDisabl 6986Connected Not conn 7086Example Keypad settings7186 Keypad settings Default 72867386 Parameter copy7486 20. Storing and loading of parameter sets7586 Parameter comparison7686 Information submenu7786 Counters menu7886 Trip counters submenuG1 G2 7986Expander board menu M7 Auto8086 Further keypad functionsCommissioning of the frequency converter Commissioning8186 8286 8386 Fault tracing 84868586 Bulgaria