Fan control (P6.3.4)

This function allows the control of the frequency converter’s cooling fan. When the power is switched on the fan can be set to run continuously or dependant on the temperature of the unit. If the latter function has been selected the fan is switched on automatically when the heat sink temperature reaches 60° C. The fan receives a stop command when the heat sink temperature falls to 55° C. However the fan runs for about a minute after receiving the stop command, as well as after changing the value from Continuous to Temperature.

Enter the edit mode by pushing the right arrow menu button. The present mode shown starts to blink. Use the Browser buttons to change the fan mode. Accept the change with the Enter button or return to the previous level with the left arrow menu button.

READY

READY

 

 

READY

I/O term

I/O term

 

 

I/O term

Fan control

Fan control

OR:

enter

Fan control

Continuous

Continuous

 

 

Temperature

Figure 7-14. Fan control function

HMI acknowledge timeout (P6.3.6)

This function allows the user to change the timeout of the HMI acknowledgement time.

Note! If the frequency converter has been connected to the PC with a normal cable, the default values of parametres 6.3.6 and 6.3.7 (200 and 5) must not be changed.

If the frequency converter has been connected to the PC via a modem and there is a delay in transferring messages, the value of par. 6.3.6 must be set according to the delay as follows:

Image 70
Contents NX series Start-up Quick Guide Contents NX USER’S Manual 486 Application Manual586 Index686 Control KeypadSafety instructions Safety786 Running the motor Earthing and earth fault protection= Dangerous voltage = General warning Technical criteria GeneralNX frequency converter EMC classification Class N 1086Class T Manufacturers declaration of conformityEU Declaration of Conformity 1186Type designation code 1286Receipt of shipment StorageWarranty Maintenance1386 1486 Technical dataIntroduction 1586 1686 Power ratings1 NX5 Mains voltage 380-500 1786 CharacteristricsTechnical data 18861986 InstallationMounting 2086 Installation NX dimensions, IP21Installation 2186 NX dimensions, IP21 with collar, FR4 to FR62286 Installation Opening needed for the collar installation, FR4 to FR6Installation 2386 NX dimensions, IP21 with collar, FR7 and FR82486 Installation Opening needed for the collar installation, FR7/FR82586 CoolingPower loss as function of switching frequency Power loss2686 Power loss as function of switching frequency 0038…0061NX5 27862886 Power unitCabling and connections External RFI-filter Filter Option 2986Motor cable Power connectionsMains cable Control cable3186 Cable and fuse sizesInstallation instructions 32863386 3486 Stripping lengths of motor and mains cablesNX frequency converter frames and installation of cables 35863686 NX, FR5. Protection class IP213786 NX, FR6. Protection class IP213886 10. NX, FR7. Protection class IP213986 Cable installation and the UL standardsCable and motor insulation checks Control unit 4086Control connections NXOPTA1 4186Control cables Galvanic isolation barriersControl terminal signals 4386+24V Ground Digital input signal inversions4486 +24VJumper block AI1 mode AI2 mode 4586Indications on the Keypad display 4686Control keypad Drive status indications See control keypadControl place indications See control keypad See .3.4, Active Faults4786 Status LEDs green green red See control keypad4886 Button descriptions ResetKeypad push-buttons SelectNavigation on the control keypad No editing 51865286 Monitoring menu M15386 Parameter menu M25486 P1 P18 Selection of control place Keypad control menu M3Select the keypad as the active control place by keeping Control placeKeypad reference Keypad directionFault types Active faults menu M45886 Fault type symbol Meaning 5986Fault codes 6086Fault code Possible cause Correcting measures 6186Fault time data record 6286Fault history menu M5 63866486 System menu M66586 Functions in the System menuCode Function Min Max Unit Default Cust Selections 6686Application selection 6786Language selection System settings 6886ChangeEnable ChangeDisabl 6986Connected Not conn 70867186 Keypad settingsExample Keypad settings Default 72867386 Parameter copy7486 20. Storing and loading of parameter sets7586 Parameter comparison7686 Information submenu7786 Counters menu7886 Trip counters submenuG1 G2 7986Expander board menu M7 Auto8086 Further keypad functions8186 CommissioningCommissioning of the frequency converter 8286 8386 Fault tracing 84868586 Bulgaria