Hand Held Products 5700 manual Bull BDS-7 Wyse WY-60/150, Honeywell, HDS-7 HP 700/92 Keyboards

Page 75

Supported Interface Keys

 

 

Bull BDS–7

 

WYSE WY–60/150

Supported

(Honeywell

 

(ASCII/ANSI

Interface Keys

HDS–7)

HP 700/92

keyboards)

NUL

00

Reserved

Reserved

Reserved

SOH

01

Transmit

Enter

Enter

STX

02

Reserved

Caps

PF1

ETX

03

Reserved

Reserved

PF2

EOT

04

Reserved

Reserved

PF3

ENQ

05

Backtab

Reserved

PF11

ACK

06

Reserved

Reserved

PF12

BEL

07

Carriage Return

Reserved

New Line

BS

08

Back Space

Back Space

PF4

HT

09

Tab

Tab

TAB

LF

0A

F11

Reserved

F13

VT

0B

F12

Reserved

F14

FF

0C

Delete Character

Reserved

Remove

CR

0D

Carriage Return

Return

New Line

SO

0E

Insert

Reserved

Insert Here

SI

0F

Clear

Reserved

Cursor Up

DLE

10

Error Reset

Home

Cursor Left

DC1

11

Home

Reserved

Cursor Down

DC2

12

Delete Line

Reserved

Cursor Right

DC3

13

Erase EOP

Reserved

Delete

DC4

14

Erase EOF

Reserved

Print

NAK

15

Insert Line

Clear Screen

F15

SYN

16

F1

F1

F1

ETB

17

F2

F2

F2

CAN

18

F3

F3

F3

EM

19

F4

F4

F4

SUB

1A

F5

F5

F5

ESC

1B

F6

Escape

F6

FS

1C

F7

F6

F7

GS

1D

F8

F7

F8

RS

1E

F9

F8

F9

US

1F

F10

Reserved

F10

 

 

 

 

 

SCANTEAM 5700 User’s Guide

6–5

Image 75
Contents Decoded Output Disclaimer A. Statement Scanteam 5700 User’s GuideFCC Class B Compliance Statement Canadian NoticePatents Table of Contents Foreign Keyboard Selection Protocol Selection Serial Wedge Output SelectionRequire Data Format Data Format Editor Marker Beam Selection AutoTrigger SelectionKeyboard Function Relationships Supported Interface Keys Industrial Symbology SelectionsObtaining Factory Service Technical Support Maintenance TroubleshootingIntroduction Scanner Identification Model Number 5X00/A-12Cable, Keyboard, and Terminal will vary Connecting the ScannerScanteam 5700/A Scanteam 5700/HD Scanteam 5700ALR IBM PC XT and Compatibles Interface IBM PC AT and Compatibles Interface DefaultIBM PC, Wand Emulation Interface IBM PS/2 and Compatibles InterfaceIBM 4683 Interface Code EANCode Ocia Interface OCR, RS232 Interface Supported Terminals Program Terminal InterfaceTerminal Models Terminal I.D ICL Reset Factory Settings Status CheckQuick Suffix Selections Dual Interface Programming Notes Dual Interface Programming InstructionsLaser Emulation Selection Code 39 Wand Emulation SelectionSame Code Wand Emulation Selection RS-232 SelectionDual Interface Enable/Disable Selection Switched Power Mode SelectionsLaser Emulation Power Up Delay Selection Introduction Primary Interface Prefix and Suffix Primary Interface Prefix Selection Primary Interface Suffix SelectionExit Selection for Prefix / Suffix Secondary Dual Interface Prefix and Suffix Secondary Interface Suffix Selection Secondary Interface Prefix SelectionExample 4 To Clear a Specific Prefix Entry Example 1 Add Suffix for Specific SymbologyExample 2 Add Suffix for ALL Symbologies Prefix and Suffix ExamplesValue Symbology Code HexOutput Delays Selection Beeper Volume SelectionReread Delay Selection Good Read Delay SelectionLaser Voting Selection Function Code Transmit Selection Buffered Scans SelectionCode I.D. Transmit Selection AIM I.D. Transmit SelectionBaud Rate Selection CTS Check SelectionParity Selection RS-232 Word Length SelectionSerial Wedge Output Selection Protocol Selection➍ Length ➎ Editor Command Sequences➋ Terminal Type ➌ Code I.DData Format Editor Require Data FormatMiscellaneous Commands Send CommandsMove Commands Search CommandsUPC a with 5 digit addenda Data Formatter ExampleScanteam 5700 User’s Guide Introduction AutoTrigger Selection Marker Beam SelectionTransmission Rate Selection Wake Up Pulse SelectionOutput Polarity Selection Foreign Keyboard Selection NCR 7052 Keypad Selection AT Direct Connect SelectionKeyboard Style Keyboard Style SelectionsKeyboard Style Selections Keyboard Style Modifiers Code 39 Selections Message Length Codabar SelectionCheck Character Append Code 39 SelectionMinimum Maximum Code 93 Selection Full Ascii ChartCheck Digit Interleaved 2 of 5 SelectionMatrix 2 of 5 Selection Code 2 of 5 SelectionCode 128 Selection Code 11 SelectionCode 128 Function Character Selection Code 49 Selection Code 16K SelectionIsbn EAN SelectionUPC E1 UPC SelectionUPC Addenda Selection EAN Addenda SelectionPlessey Selection MSI SelectionScanteam 5700 User’s Guide Page Memory Upload Scanteam 5700 User’s Guide Download New FirmwareClone Destination Clone Master+ a Scanteam 5700 User’s Guide Scanteam 5700 User’s Guide Keyboard Function Relationships Function Code HEX/ASCII Value Full Ascii Ctrl +Country Codes IBM AT/XT PS/2 Compatibles, IBM XTs Memorex TelexCompatibles Harris Telex IBM, MemorexAnsi Ascii Supported Esprit 200Bull BDS-7 Wyse WY-60/150 HoneywellHDS-7 HP 700/92 Keyboards Supported Interface Keys Scanteam 5700 Product Specifications Laser Output only Pin Type D Female 5700-X4 Laser Compatible Bar Image +12VDC InputWand Emulation RS-232 Laser Output Cleaning the Scan Window MaintenanceReplacing the Interface Cable Is the scanner having trouble reading your bar codes? Example You scan 12345 and the host displays A12345B Welch Allyn, Inc Obtaining Factory ServiceWelch Allyn North AmericaEurope Limited Warranty Scanteam 5700 User’s Guide Output Selections Serial Interface Menu DefaultsKeyboard Selections General Operating Menu DefaultsCodabar Selections Symbology Menu Defaults IndustrialCode 11 Selections EAN / UPC Addenda Selections Symbology Menu Defaults RetailScanteam 5700 User’s Guide Page Page Page Code 2 EANInterleaved 2 Matrix 2