Hand Held Products manual Scanteam 5700 Product Specifications

Page 77

SCANTEAM 5700 Product Specifications

Parameter

Specification

Dimensions

7 ounces (198 g)

Weight

Length

5.8 inches (14.8 cm)

Height

5.8 inches (14.8 cm)

Width

3.0 inches (7.6 cm)

 

 

Light Source

670 nm visible laser diode (VLD); 5700ALR = 650nm

 

VLD

 

 

Scan Rate

36 ±3 scans per second

 

 

Print Contrast

Minimum Reflective Difference = 25% (5700/A);

 

MRD = 40% (5700ALR, 5700/HD)

 

 

Skew Angle

±65 degrees (from perpendicular) – 5700/A

 

±60 degrees (from perpendicular) – 5700/HD,

 

5700ALR

 

 

Pitch Angle

±55 degrees (left/right from perpendicular) – 5700/A

 

±65 degrees (left/right from perpendicular) – 5700/HD,

 

5700ALR

 

 

Operating Voltage

 

Non-Decoded

+4.5 to 5.5 VDC (57–04 model only supports +12VDC

Decoded

input with unique cable)

Either +5 VDC or +12 VDC, depending on interface

 

 

Power Consumption

 

Non-Decoded +5VDC

0.060 mA Idle, 110 mA Scanning; (135mA – 5700ALR)

Non-Decoded +12VDC

10 mA Idle, 110 mA Scanning; (145mA – 5700ALR)

Decoded +5VDC

60 to 90 mA Idle],, 165 to 200 mA Scanning

Decoded +12VDC

105 mA Idle], 210 mA Scanning

 

 

Temperature Ranges

Operating 32° F to +104° F (–0°C to +40° C)

 

Storage –40°F to +140° F (–40°C to +60° C)

 

 

Humidity

5 to 95% non-condensing

 

 

Mechanical Shock

5 drops from 5 feet (1.5m) to concrete

 

(5700/A/HD/ALR)

 

 

ESD Sensitivity

15 kV to any external surface

 

 

Agency Compliance

FCC Class B, CE, LVD, CDRH Class II (Class IIIa for

 

5700ALR)

 

 

] When operated in switched power mode, idle current is less than 0.06 mA.

SCANTEAM 5700 User’s Guide

7–1

Image 77
Contents Decoded Output Disclaimer FCC Class B Compliance Statement Scanteam 5700 User’s GuideCanadian Notice A. StatementPatents Table of Contents Require Data Format Data Format Editor Protocol Selection Serial Wedge Output SelectionMarker Beam Selection AutoTrigger Selection Foreign Keyboard SelectionKeyboard Function Relationships Supported Interface Keys Industrial Symbology SelectionsObtaining Factory Service Technical Support Maintenance TroubleshootingIntroduction Scanner Identification Model Number 5X00/A-12Cable, Keyboard, and Terminal will vary Connecting the ScannerScanteam 5700/A Scanteam 5700/HD Scanteam 5700ALR IBM PC, Wand Emulation Interface IBM PC AT and Compatibles Interface DefaultIBM PS/2 and Compatibles Interface IBM PC XT and Compatibles InterfaceCode IBM 4683 InterfaceCode EAN Ocia Interface OCR, RS232 Interface Terminal Models Terminal I.D Supported TerminalsProgram Terminal Interface ICL Quick Suffix Selections Reset Factory SettingsStatus Check Dual Interface Programming Notes Dual Interface Programming InstructionsSame Code Wand Emulation Selection Code 39 Wand Emulation SelectionRS-232 Selection Laser Emulation SelectionLaser Emulation Power Up Delay Selection Dual Interface Enable/Disable SelectionSwitched Power Mode Selections Introduction Primary Interface Prefix and Suffix Exit Selection for Prefix / Suffix Primary Interface Prefix SelectionPrimary Interface Suffix Selection Secondary Dual Interface Prefix and Suffix Secondary Interface Suffix Selection Secondary Interface Prefix SelectionExample 2 Add Suffix for ALL Symbologies Example 1 Add Suffix for Specific SymbologyPrefix and Suffix Examples Example 4 To Clear a Specific Prefix EntryValue Symbology Code HexOutput Delays Selection Beeper Volume SelectionLaser Voting Selection Reread Delay SelectionGood Read Delay Selection Code I.D. Transmit Selection Buffered Scans SelectionAIM I.D. Transmit Selection Function Code Transmit SelectionBaud Rate Selection CTS Check SelectionParity Selection RS-232 Word Length SelectionSerial Wedge Output Selection Protocol Selection➋ Terminal Type ➎ Editor Command Sequences➌ Code I.D ➍ LengthData Format Editor Require Data FormatMove Commands Send CommandsSearch Commands Miscellaneous CommandsUPC a with 5 digit addenda Data Formatter ExampleScanteam 5700 User’s Guide Introduction AutoTrigger Selection Marker Beam SelectionOutput Polarity Selection Transmission Rate SelectionWake Up Pulse Selection Foreign Keyboard Selection NCR 7052 Keypad Selection AT Direct Connect SelectionKeyboard Style Keyboard Style SelectionsKeyboard Style Selections Keyboard Style Modifiers Code 39 Selections Message Length Codabar SelectionCheck Character Append Code 39 SelectionMinimum Maximum Code 93 Selection Full Ascii ChartCheck Digit Interleaved 2 of 5 SelectionMatrix 2 of 5 Selection Code 2 of 5 SelectionCode 128 Selection Code 11 SelectionCode 128 Function Character Selection Code 49 Selection Code 16K SelectionIsbn EAN SelectionUPC E1 UPC SelectionUPC Addenda Selection EAN Addenda SelectionPlessey Selection MSI SelectionScanteam 5700 User’s Guide Page Memory Upload Scanteam 5700 User’s Guide Download New Firmware+ a Scanteam 5700 User’s Guide Clone DestinationClone Master Scanteam 5700 User’s Guide Country Codes Keyboard Function RelationshipsFunction Code HEX/ASCII Value Full Ascii Ctrl + Compatibles Harris IBM AT/XTPS/2 Compatibles, IBM XTs Memorex Telex Telex IBM, MemorexAnsi Ascii Supported Esprit 200HDS-7 HP 700/92 Keyboards Bull BDS-7 Wyse WY-60/150Honeywell Supported Interface Keys Scanteam 5700 Product Specifications Laser Output only Pin Type D Female 5700-X4 Laser Compatible Bar Image +12VDC InputWand Emulation RS-232 Laser Output Cleaning the Scan Window MaintenanceReplacing the Interface Cable Is the scanner having trouble reading your bar codes? Example You scan 12345 and the host displays A12345B Welch Allyn, Inc Obtaining Factory ServiceEurope Welch AllynNorth America Limited Warranty Scanteam 5700 User’s Guide Output Selections Serial Interface Menu DefaultsKeyboard Selections General Operating Menu DefaultsCodabar Selections Symbology Menu Defaults IndustrialCode 11 Selections EAN / UPC Addenda Selections Symbology Menu Defaults RetailScanteam 5700 User’s Guide Page Page Page Interleaved 2 EANMatrix 2 Code 2