Wand Emulation
5700–X1, 5700–X2
Conventional wand data format is provided at the modular connector in the scanner handle.
Interface cables normally supplied with scanner model
P1 | P2 |
10 Pin Modular Plug | 9 Pin Type D Female |
P1 connects to the | P2 connects to |
scanner handle. | your terminal. |
P1
2
3
4
6
7
Pin 1 | 5 | 1 | |
Pin 10 | 9 | 6 | |
| View | ||
|
| ||
Signal | Function | P2 | |
Braid | Cord Shield | 8 | |
Prog 1 | Tied to 5 Volt Power | ||
| |||
Ground | Supply Ground | 7 | |
Barcode | Bar Code Data Output | ||
2 | |||
+5VDC | 5 Volt Power Connection | ||
4 | |||
|
|