Symbology Menu Defaults – Retail

The following chart lists the factory default Retail Symbology Menu settings (indicated by a “” on the programming menu pages).

Parameter Name

Default Setting

Page

Reference

 

 

EAN Selections

 

 

EAN / JAN 13

On

Page 4–12

EAN / JAN 8

On

Page 4–12

Check Digit

Transmit

Page 4–12

ISBN

Disable

Page 4–12

UPC Selections

 

 

UPC A

On

Page 4–13

UPC E0

On

Page 4–13

UPC E1

Off

Page 4–13

Check Digit

Transmit

Page 4–13

Number System

Transmit

Page 4–13

Version E Expand

Don’t Expand

Page 4–13

EAN / UPC Addenda Selections

 

EAN / UPC Addenda

Don’t Require

Page 4–14

EAN / UPC Addenda Format

Space

Page 4–14

EAN Addenda

 

 

Two Digit Addenda

Disable

Page 4–14

Five Digit Addenda

Disable

Page 4–14

UPC Addenda

 

 

Two Digit Addenda

Disable

Page 4–14

Five Digit Addenda

Disable

Page 4–14

MSI Selections

 

 

MSI

Off

Page 4–15

Message Length

Min = 4, Max = 48

Page 4–15

Plessey Selections

 

 

Plessey

Off

Page 4–15

Message Length

Min = 4, Max = 48

Page 4–15

 

 

 

SCANTEAM 5700 User’s Guide

Image 95
Contents Decoded Output Disclaimer A. Statement Scanteam 5700 User’s GuideFCC Class B Compliance Statement Canadian NoticePatents Table of Contents Foreign Keyboard Selection Protocol Selection Serial Wedge Output SelectionRequire Data Format Data Format Editor Marker Beam Selection AutoTrigger SelectionKeyboard Function Relationships Supported Interface Keys Industrial Symbology SelectionsObtaining Factory Service Technical Support Maintenance TroubleshootingIntroduction Scanner Identification Model Number 5X00/A-12Cable, Keyboard, and Terminal will vary Connecting the ScannerScanteam 5700/A Scanteam 5700/HD Scanteam 5700ALR IBM PC XT and Compatibles Interface IBM PC AT and Compatibles Interface DefaultIBM PC, Wand Emulation Interface IBM PS/2 and Compatibles InterfaceCode IBM 4683 InterfaceCode EAN Ocia Interface OCR, RS232 Interface Terminal Models Terminal I.D Supported TerminalsProgram Terminal Interface ICL Quick Suffix Selections Reset Factory SettingsStatus Check Dual Interface Programming Notes Dual Interface Programming InstructionsLaser Emulation Selection Code 39 Wand Emulation SelectionSame Code Wand Emulation Selection RS-232 SelectionLaser Emulation Power Up Delay Selection Dual Interface Enable/Disable SelectionSwitched Power Mode Selections Introduction Primary Interface Prefix and Suffix Exit Selection for Prefix / Suffix Primary Interface Prefix SelectionPrimary Interface Suffix Selection Secondary Dual Interface Prefix and Suffix Secondary Interface Suffix Selection Secondary Interface Prefix SelectionExample 4 To Clear a Specific Prefix Entry Example 1 Add Suffix for Specific SymbologyExample 2 Add Suffix for ALL Symbologies Prefix and Suffix ExamplesValue Symbology Code HexOutput Delays Selection Beeper Volume SelectionLaser Voting Selection Reread Delay SelectionGood Read Delay Selection Function Code Transmit Selection Buffered Scans SelectionCode I.D. Transmit Selection AIM I.D. Transmit SelectionBaud Rate Selection CTS Check SelectionParity Selection RS-232 Word Length SelectionSerial Wedge Output Selection Protocol Selection➍ Length ➎ Editor Command Sequences➋ Terminal Type ➌ Code I.DData Format Editor Require Data FormatMiscellaneous Commands Send CommandsMove Commands Search CommandsUPC a with 5 digit addenda Data Formatter ExampleScanteam 5700 User’s Guide Introduction AutoTrigger Selection Marker Beam SelectionOutput Polarity Selection Transmission Rate SelectionWake Up Pulse Selection Foreign Keyboard Selection NCR 7052 Keypad Selection AT Direct Connect SelectionKeyboard Style Keyboard Style SelectionsKeyboard Style Selections Keyboard Style Modifiers Code 39 Selections Message Length Codabar SelectionCheck Character Append Code 39 SelectionMinimum Maximum Code 93 Selection Full Ascii ChartCheck Digit Interleaved 2 of 5 SelectionMatrix 2 of 5 Selection Code 2 of 5 SelectionCode 128 Selection Code 11 SelectionCode 128 Function Character Selection Code 49 Selection Code 16K SelectionIsbn EAN SelectionUPC E1 UPC SelectionUPC Addenda Selection EAN Addenda SelectionPlessey Selection MSI SelectionScanteam 5700 User’s Guide Page Memory Upload Scanteam 5700 User’s Guide Download New Firmware+ a Scanteam 5700 User’s Guide Clone DestinationClone Master Scanteam 5700 User’s Guide Country Codes Keyboard Function RelationshipsFunction Code HEX/ASCII Value Full Ascii Ctrl + Compatibles Harris IBM AT/XTPS/2 Compatibles, IBM XTs Memorex Telex Telex IBM, MemorexAnsi Ascii Supported Esprit 200HDS-7 HP 700/92 Keyboards Bull BDS-7 Wyse WY-60/150Honeywell Supported Interface Keys Scanteam 5700 Product Specifications Laser Output only Pin Type D Female 5700-X4 Laser Compatible Bar Image +12VDC InputWand Emulation RS-232 Laser Output Cleaning the Scan Window MaintenanceReplacing the Interface Cable Is the scanner having trouble reading your bar codes? Example You scan 12345 and the host displays A12345B Welch Allyn, Inc Obtaining Factory ServiceEurope Welch AllynNorth America Limited Warranty Scanteam 5700 User’s Guide Output Selections Serial Interface Menu DefaultsKeyboard Selections General Operating Menu DefaultsCodabar Selections Symbology Menu Defaults IndustrialCode 11 Selections EAN / UPC Addenda Selections Symbology Menu Defaults RetailScanteam 5700 User’s Guide Page Page Page Code 2 EANInterleaved 2 Matrix 2