Sennheiser SET100 manual

Page 15

Additional information for helicopter use of the HME 120 headset

The polarity of the microphone connection in helicopters is not standardized. If the microphone of your headset does not work with the existing polarity, you can reverse the polarity on the headset by simply rotating the microphone module. To do so, please proceed as follows:

1.Pull the wind screen from the microphone.

2.Loosen the screws by approx. half a turn.

3.Pull the microphone module from the boom-arm.

4.Rotate the microphone module by 180°.

5.Put the rotated microphone module back into the boom-arm.

6.Now tighten the screws from the other side.

7.Slide the windscreen over the microphone.

Rotating the microphone module does not change its acoustic properties. Due to its noise- compensating pick-up pattern, the microphone can be used from either side.

39

Image 15
Contents Headset Contents Safety tips HME 100 headset Headset featuresProduct variants HME 105 headsetHME 120 headset HMD 120 headset HME 100, HME 105 and HME 120 headsets Recommended AccessoriesDelivery includes Connecting the headsets Preparing the headsets for useHME 120 and HMD 120 headsets Adjusting the headband Positioning the microphone Relocating the microphone boomPositioning the microphone towards the corner of the mouth Page Using the headsets Adjusting the volumeMono/Stereo selection HME 100 only Folding up the headphones Adjusting the microphone gainPage Spare parts Replacing the wind screenReplacing the ear cushions Connector assignment Problem Case of difficultyPossible cause and what to do Microphone output voltage too high or too low HME HME 105 and HME HMD Technical dataHMD HMECertificate of Conformity 136