Error Code | Message Information |
|
PSU1201 | Message | Power supply redundancy is lost. |
| ||
| Details | The power supply tries to operate in a degraded state. System |
|
| Performance and power redundancy may be degraded or lost. |
| Action | Check input power. Reinstall the power supply. If the issue persists, |
|
| see Getting Help. |
PSU1204 | Message | The power supplies are not redundant. Insufficient resources to |
| ||
|
| maintain normal operations. |
| Details | The current power operational mode is |
|
| power supply exception, a power supply inventory change, or a |
|
| system power inventory change. |
| Action | Check the event log for power supply failures. Review system |
|
| configuration and power consumption. |
PWR1004 | Message | The system performance degraded because power capacity has |
| ||
|
| changed. |
| Details | The system may power down or operate in a performance degraded |
|
| state. |
| Action | Check the event log for power supply failures. Review system |
|
| configuration and power consumption and upgrade or install power |
|
| supplies accordingly. |
PWR1005 | Message | The system performance degraded because the |
| ||
|
| capacity has changed. |
| Details | The |
| Action | If unintended, review system configuration changes and power |
|
| policy. |
PWR1006 | Message | The system halted because system power exceeds capacity. |
| ||
| Details | The system halted because system power exceeds capacity. |
| Action | Review system configuration, upgrade power supplies or reduce |
|
| system power consumption. |
RFM1008 | Message | Failure detected on Removable Flash Media <name>. |
| ||
| Details | An error was reported during a SD card read or write. |
| Action | Reseat the flash media. If the problem persists, see Getting Help. |
113