Dell DR4100 System Setup Options, Responding To Error Messages, System Setup Main Screen

Page 16

Responding To Error Messages

If an error message is displayed while the system is booting, make a note of the message. For more information, see System Error Messages.

NOTE: After installing a memory upgrade, it is normal for your system to display a message the first time you start your system.

Using The System Setup Navigation Keys

Keys

Action

Up arrow

Moves to the previous field.

Down arrow

Moves to the next field.

<Enter>

Allows you to type in a value in the selected field (if applicable) or follow the link in the field.

Spacebar

Expands or collapses a drop-down list, if applicable.

<Tab>

Moves to the next focus area.

 

NOTE: For the standard graphics browser only.

<Esc>

Moves to the previous page until you view the main screen. Pressing <Esc>in the main screen

 

displays a message that prompts you to save any unsaved changes and restarts the system.

<F1>

Displays the System Setup help file.

NOTE: For most of the options, any changes that you make are recorded but do not take effect until you restart the system.

System Setup Options

System Setup Main Screen

NOTE: Unified Extensible Firmware Interface (UEFI) Boot Manager is not supported. BIOS Boot Manager is the default boot mode.

Menu Item

Description

System BIOS

This option is used to view and configure BIOS settings.

iDRAC Settings

This option is used to view and configure iDRAC settings.

Device Settings

This option is used to view and configure device settings.

System BIOS Screen

NOTE: The options for System Setup change based on the system configuration.

16

Image 16
Contents Regulatory Model E14S Series Regulatory Type E14S001 Dell Inc Contents Installing System Components Troubleshooting Your System Safety First-For You And Your SystemUsing System Diagnostics Jumpers And ConnectorsTechnical Specifications System Messages Getting HelpFront-Panel Features And Indicators Indicator, Button, or Icon Description ConnectorDiagnostic Indicators Health indicator ConditionHard-drive indicator Condition Corrective ActionHard-drive indicator Condition Corrective Action Electrical indicator ConditionMemory indicator Corrective Action ProgramHard-Drive Indicator Patterns PCIe indicator ConditionError Drive-Status Condition Indicator Pattern RAID OnlyBack-Panel Features And Indicators SecondsNIC Indicator Codes Green Link indicator isPower Indicator Codes Other Information You May NeedPage Entering System Setup Keystroke Description Enters the System Setup F10System Setup Options Responding To Error MessagesUsing The System Setup Navigation Keys System Setup Main ScreenMemory Settings Screen System Information ScreenProcessor Settings Screen Boot Settings Screen Integrated Devices Screen Serial Communications ScreenSystem Profile Settings Screen System Security Screen System And Setup Password Features Miscellaneous SettingsAssigning a System And/Or Setup Password Using Your System Password To Secure Your System Operating With a Setup Password EnabledBoot Manager Screen Using The Boot Manager Navigation KeysEmbedded System Management IDRAC Settings Utility Entering The iDRAC Settings UtilityPage Recommended Tools Inside The SystemFront Bezel Optional Removing The Front BezelOpening And Closing The System Installing The Front BezelOpening The System Closing The System Cooling ShroudRemoving The Cooling Shroud Installing The Cooling Shroud Removing and Installing the Cooling ShroudSystem Memory Processor Channel 0 slots A1, A5, and A9General Memory Module Installation Guidelines Mode-Specific GuidelinesMemory Configuration Removing Memory ModulesInstalling Memory Modules Removing and Installing a Memory ModuleHard Drives Removing a 2.5 Inch Hard-Drive Blank Back Installing a 2.5 Inch Hard-Drive Blank BackRemoving a 3.5 Inch Hard-Drive Blank Installing a 3.5 Inch Hard-Drive Blank Removing a Hot-Swap Hard DriveInstalling a Hot-Swap Hard Drive Removing and Installing a Hot-Swap Hard DriveCooling Fans Installing a Hard Drive Into a Hard-Drive CarrierRemoving a Hard Drive From a Hard-Drive Carrier Removing and Installing a Cooling Fan Removing a Cooling FanInstalling a Cooling Fan Removing The Cooling-Fan AssemblyInternal USB Memory Key Optional Installing The Cooling-Fan AssemblyReplacing The Internal USB Key PCIe Card Holder Removing The PCIe Card HolderInstalling The PCIe Card Holder Opening And Closing The PCIe Card Holder LatchCable Retention Bracket Removing The Cable Retention BracketExpansion Card Installation Guidelines Installing The Cable Retention BracketExpansion Cards And Expansion-Card Risers Height Length Link Width Slot Width Riser PCIe SlotCard Priority Card Type Slot Priority Max Allowed Unpack the expansion card and prepare it for installation Removing An Expansion Card From The Expansion-Card Riser Installing An Expansion Card Into The Expansion-Card Riser Removing and Installing the Expansion-Card RiserRemoving and Installing the Expansion Card Riser Removing Expansion-Card RisersExpansion-card slot Chassis intrusion switch Expansion-card slot Internal Dual SD Module Installing Expansion-Card RisersRemoving The Internal Dual SD Module Installing The Internal Dual SD Module Removing and Installing the Internal Dual SD ModuleIntegrated Storage Controller Card Removing The Integrated Storage Controller CardInstalling The Integrated Storage Controller Card Network Daughter Card Removing The Network Daughter CardProcessors Installing The Network Daughter CardRemoving a Processor Removing and Installing the Processor Heat Sink Processor Shield Opening and Closing Lever Sequence Installing a Processor Removing and Installing a ProcessorPower Supplies Your system supports two 750 W power supply modulesPower Supply Hot Spare Feature Removing An AC Power SupplyInstalling An AC Power Supply Removing The Power Supply BlankInstalling The Power Supply Blank System BatteryReplacing The System Battery Hard-Drive Backplane Removing The Hard-Drive BackplaneUSB cable SAS cables Installing The Hard-Drive Backplane Cabling Diagram-3.5 Inch x12 SAS BackplaneRemoving The Hard-Drive Backplane Back Installing The Hard-Drive Backplane Back Panel Removing The I/O PanelInstalling The I/O Panel Removing and Installing the I/O PanelSystem Board Removing The System BoardSystem board System-board holder Release pin Installing The System Board Troubleshooting The Video Subsystem Troubleshooting External ConnectionsTroubleshooting a USB Device Troubleshooting a NIC Troubleshooting a Serial I/O DeviceTroubleshooting a Wet System Troubleshooting a Damaged System Troubleshooting Power Supplies Troubleshooting The System BatteryTroubleshooting Cooling Problems Troubleshooting System Memory Troubleshooting Cooling FansTroubleshooting An Internal USB Key Troubleshooting An SD CardTroubleshooting a Hard Drive Troubleshooting a Storage ControllerTroubleshooting Expansion Cards Troubleshooting Processors Page Dell Embedded System Diagnostics When To Use The Embedded System DiagnosticsRunning The Embedded System Diagnostics System Diagnostic ControlsLeast one event description is recorded System Board Jumper Settings Jumper Setting DescriptionSystem Board Connectors Jidsdm Jndc JRISER3A JRISER3BJvideorear Disabling a Forgotten Password Connector DescriptionExpansion slots using riser card PowerExpansion Bus Connectors Back Expanded Operating TemperatureMemory DrivesEnvironmental Temperature Temperature Continuous OperationEnvironmental Relative humidityMaximum vibration Maximum shockGaseous Contamination 102 System Error Messages ASR0001 Message ASR0002 MessageASR0003 Message BAT0002 MessageCPU0005 Message CPU0010 MessageCPU0023 Message CPU0204 MessageCPU0703 Message CPU0702 MessageCPU0704 Message If the issue persists, see Getting Help Action Reinstall or reconnect the hardware HWC2003 MessageFAN0000 Message Details Fan operating speed is out of range ActionMEM0001 Message MEM0007 MessageMEM0701 Message MEM0702 MessageMEM8000 Message PCI1302 MessagePCI1304 Message PCI1308 MessageReinstall the device PDR0001 Message Fault detected on drive number DetailsConfigurations PSU0001 Message Power supply number failed ActionPSU0003 Message PSU0006 MessagePSU0016 Message PSU0031 MessagePSU0033 Message PSU0034 MessagePSU0035 Message PSU0036 MessagePSU1201 Message Power supply redundancy is lost Details System power inventory changeConfiguration and power consumption System power consumptionRFM1014 Message RFM1201 MessageRFM2001 Message RFM2002 MessageSEL0006 Message All event logging is disabled Details Appear if the user disabled event loggingPower. If problem persists call support Issues persists, contact supportDiagnostic Messages FailedFailures TMP0121 MessageAlert Messages 118 Contacting Dell Visit support.dell.com