Dell DR4100 owner manual General Memory Module Installation Guidelines, Mode-Specific Guidelines

Page 36

General Memory Module Installation Guidelines

This system supports Flexible Memory Configuration, enabling the system to be configured and run in any valid chipset architectural configuration. The following are the recommended guidelines for best performance:

x4 and x8 DRAM based DIMMs can be mixed. For more information, see Mode-Specific Guidelines.

Up to two quad-rank RDIMMs and up to three dual- or single-rank RDIMMs can be populated per channel. When a quad-rank RDIMM is populated in the first slot with white release levers, the third DIMM slot in the channel with green release levers cannot be populated.

Populate DIMM sockets only if a processor is installed. For single-processor systems, sockets A1 to A12 are available. For dual-processor systems, sockets A1 to A12 and sockets B1 to B12 are available.

Populate all sockets with white release tabs first, then black, and then green.

Do not populate the third DIMM socket in a channel with green release tabs, if a quad-rank RDIMM is populated in the first socket with white release tabs.

Populate the sockets by highest rank count in the following order — first in sockets with white release levers, then black, and then green. For example, if you want to mix quad-rank and dual-rank DIMMs, populate quad- rank DIMMs in the sockets with white release tabs and dual-rank DIMMs in the sockets with black release tabs.

In a dual-processor configuration, the memory configuration for each processor should be identical. For example, if you populate socket A1 for processor 1, then populate socket B1 for processor 2, and so on.

Memory modules of different sizes can be mixed provided that other memory population rules are followed (for example, 2 GB and 4 GB memory modules can be mixed).

Populate four DIMMs per processor (one DIMM per channel) at a time to maximize performance.

If memory modules with different speeds are installed, they will operate at the speed of the slowest installed memory module(s) or slower depending on system DIMM configuration.

Mode-Specific Guidelines

Four memory channels are allocated to each processor. The allowable configurations depend on the memory mode selected.

NOTE: x4 and x8 DRAM based DIMMs can be mixed providing support for RAS features. However, all guidelines for specific RAS features must be followed. x4 DRAM based DIMMs retain Single Device Data Correction (SDDC) in memory optimized (independent channel) mode. x8 DRAM based DIMMs require Advanced ECC mode to gain SDDC.

The following sections provide additional slot population guidelines for each mode.

Advanced ECC (Lockstep)

Advanced ECC mode extends SDDC from x4 DRAM based DIMMs to both x4 and x8 DRAMs. This protects against single DRAM chip failures during normal operation.

Memory installation guidelines:

Memory modules must be identical in size, speed, and technology.

DIMMs installed in memory sockets with white release tabs must be identical and similar rule applies for sockets with black and green release tabs. This ensures that identical DIMMs are installed in matched pairs - for example, A1 with A2, A3 with A4, A5 with A6, and so on.

NOTE: Advanced ECC with Mirroring is not supported.

36

Image 36
Contents Regulatory Model E14S Series Regulatory Type E14S001 Dell Inc Contents Installing System Components Troubleshooting Your System Safety First-For You And Your SystemUsing System Diagnostics Jumpers And ConnectorsTechnical Specifications System Messages Getting HelpFront-Panel Features And Indicators Indicator, Button, or Icon Description ConnectorDiagnostic Indicators Health indicator ConditionHard-drive indicator Condition Corrective ActionHard-drive indicator Condition Corrective Action Electrical indicator ConditionMemory indicator Corrective Action ProgramHard-Drive Indicator Patterns PCIe indicator ConditionError Drive-Status Condition Indicator Pattern RAID OnlyBack-Panel Features And Indicators SecondsNIC Indicator Codes Green Link indicator isPower Indicator Codes Other Information You May NeedPage Entering System Setup Keystroke Description Enters the System Setup F10System Setup Options Responding To Error MessagesUsing The System Setup Navigation Keys System Setup Main ScreenMemory Settings Screen System Information ScreenProcessor Settings Screen Boot Settings Screen Integrated Devices Screen Serial Communications ScreenSystem Profile Settings Screen System Security Screen System And Setup Password Features Miscellaneous SettingsAssigning a System And/Or Setup Password Using Your System Password To Secure Your System Operating With a Setup Password EnabledUsing The Boot Manager Navigation Keys Boot Manager ScreenEmbedded System Management IDRAC Settings Utility Entering The iDRAC Settings UtilityPage Recommended Tools Inside The SystemFront Bezel Optional Removing The Front BezelInstalling The Front Bezel Opening And Closing The SystemOpening The System Cooling Shroud Closing The SystemRemoving The Cooling Shroud Installing The Cooling Shroud Removing and Installing the Cooling ShroudSystem Memory Processor Channel 0 slots A1, A5, and A9General Memory Module Installation Guidelines Mode-Specific GuidelinesMemory Configuration Removing Memory ModulesInstalling Memory Modules Removing and Installing a Memory ModuleHard Drives Installing a 2.5 Inch Hard-Drive Blank Back Removing a 2.5 Inch Hard-Drive Blank BackRemoving a 3.5 Inch Hard-Drive Blank Installing a 3.5 Inch Hard-Drive Blank Removing a Hot-Swap Hard DriveInstalling a Hot-Swap Hard Drive Removing and Installing a Hot-Swap Hard DriveInstalling a Hard Drive Into a Hard-Drive Carrier Cooling FansRemoving a Hard Drive From a Hard-Drive Carrier Removing and Installing a Cooling Fan Removing a Cooling FanInstalling a Cooling Fan Removing The Cooling-Fan AssemblyInstalling The Cooling-Fan Assembly Internal USB Memory Key OptionalReplacing The Internal USB Key PCIe Card Holder Removing The PCIe Card HolderInstalling The PCIe Card Holder Opening And Closing The PCIe Card Holder LatchCable Retention Bracket Removing The Cable Retention BracketInstalling The Cable Retention Bracket Expansion Card Installation GuidelinesExpansion Cards And Expansion-Card Risers Riser PCIe Slot Height Length Link Width Slot WidthCard Priority Card Type Slot Priority Max Allowed Unpack the expansion card and prepare it for installation Removing An Expansion Card From The Expansion-Card Riser Installing An Expansion Card Into The Expansion-Card Riser Removing and Installing the Expansion-Card RiserRemoving and Installing the Expansion Card Riser Removing Expansion-Card RisersExpansion-card slot Chassis intrusion switch Expansion-card slot Installing Expansion-Card Risers Internal Dual SD ModuleRemoving The Internal Dual SD Module Installing The Internal Dual SD Module Removing and Installing the Internal Dual SD ModuleIntegrated Storage Controller Card Removing The Integrated Storage Controller CardInstalling The Integrated Storage Controller Card Network Daughter Card Removing The Network Daughter CardInstalling The Network Daughter Card ProcessorsRemoving a Processor Removing and Installing the Processor Heat Sink Processor Shield Opening and Closing Lever Sequence Installing a Processor Removing and Installing a ProcessorPower Supplies Your system supports two 750 W power supply modulesPower Supply Hot Spare Feature Removing An AC Power SupplyInstalling An AC Power Supply Removing The Power Supply BlankSystem Battery Installing The Power Supply BlankReplacing The System Battery Hard-Drive Backplane Removing The Hard-Drive BackplaneUSB cable SAS cables Installing The Hard-Drive Backplane Cabling Diagram-3.5 Inch x12 SAS BackplaneRemoving The Hard-Drive Backplane Back Installing The Hard-Drive Backplane Back Panel Removing The I/O PanelInstalling The I/O Panel Removing and Installing the I/O PanelSystem Board Removing The System BoardSystem board System-board holder Release pin Installing The System Board Troubleshooting External Connections Troubleshooting The Video SubsystemTroubleshooting a USB Device Troubleshooting a Serial I/O Device Troubleshooting a NICTroubleshooting a Wet System Troubleshooting a Damaged System Troubleshooting The System Battery Troubleshooting Power SuppliesTroubleshooting Cooling Problems Troubleshooting System Memory Troubleshooting Cooling FansTroubleshooting An Internal USB Key Troubleshooting An SD CardTroubleshooting a Hard Drive Troubleshooting a Storage ControllerTroubleshooting Expansion Cards Troubleshooting Processors Page Dell Embedded System Diagnostics When To Use The Embedded System DiagnosticsRunning The Embedded System Diagnostics System Diagnostic ControlsLeast one event description is recorded System Board Jumper Settings Jumper Setting DescriptionSystem Board Connectors Jidsdm Jndc JRISER3A JRISER3BJvideorear Disabling a Forgotten Password Connector DescriptionPower Expansion slots using riser cardExpansion Bus Connectors Back Expanded Operating TemperatureMemory DrivesEnvironmental Temperature Temperature Continuous OperationEnvironmental Relative humidityMaximum vibration Maximum shockGaseous Contamination 102 System Error Messages ASR0001 Message ASR0002 MessageASR0003 Message BAT0002 MessageCPU0005 Message CPU0010 MessageCPU0023 Message CPU0204 MessageCPU0702 Message CPU0703 MessageCPU0704 Message If the issue persists, see Getting Help Action Reinstall or reconnect the hardware HWC2003 MessageFAN0000 Message Details Fan operating speed is out of range ActionMEM0001 Message MEM0007 MessageMEM0701 Message MEM0702 MessageMEM8000 Message PCI1302 MessagePCI1304 Message PCI1308 MessageReinstall the device PDR0001 Message Fault detected on drive number DetailsConfigurations PSU0001 Message Power supply number failed ActionPSU0003 Message PSU0006 MessagePSU0016 Message PSU0031 MessagePSU0033 Message PSU0034 MessagePSU0035 Message PSU0036 MessagePSU1201 Message Power supply redundancy is lost Details System power inventory changeConfiguration and power consumption System power consumptionRFM1014 Message RFM1201 MessageRFM2001 Message RFM2002 MessageSEL0006 Message All event logging is disabled Details Appear if the user disabled event loggingPower. If problem persists call support Issues persists, contact supportDiagnostic Messages FailedFailures TMP0121 MessageAlert Messages 118 Contacting Dell Visit support.dell.com