28Chapter 4 Installing the server and peripheral devices
To install the server
Step Action
1Place the 600r server in its chosen location. If you are installing the server in a rack cabinet, follow the instructions provided with the slide rails.
Note: The DS30X cable that connects the NTRH40AA MPB96 board to the MGate cards is 20 m (60 feet) long. With this cable, you can place the server in a different room from the Meridian 1 switch or CS 1000 system.
The DS30 cables that connect the NTRH40CA MPB96 board to the NTRB18DA MGate cards can be up to 600 m (1968 feet) long. With this cable you can place the server in a different building from the Meridian 1 switch or CS 1000 system.
2Locate the external SCSI terminator (included loose within the server shipping carton). Connect the terminator to the rear SCSI port labeled C in Figure 7 "Rear panel" (page 29). For an illustration of the SCSI terminator, see the item labeled Server terminator in Figure 8 "SCSI tape drive with terminator" (page 31).
CAUTION
It is imperative that you install the terminator to ensure reliable server operation. Failure to do so will result in an inability to load the operating system.
3Connect peripheral devices as described in this chapter.
What is next?
Connect peripheral devices as described in this chapter.
Connecting peripherals to the server
Rear panel connectors
The following diagram shows the connectors on the rear panel of the 600r.
Nortel CallPilot
600r Server Hardware Installation