Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E2016 | Int Controller | Interrupt controller failure. | See "Getting Help" on page 147. |
|
|
|
|
E2017 | Timer Fail | Timer refresh failure. | See "Getting Help" on page 147. |
|
|
|
|
E2018 | Prog Timer | Programmable interval timer | See "Getting Help" on page 147. |
|
| error. |
|
|
|
|
|
E2019 | Parity Error | Parity error. | See "Getting Help" on page 147. |
|
|
|
|
E201A | SIO Err | SIO failure. | See "Getting Help" on page 147. |
|
|
|
|
E201B | Kybd Controller | Keyboard controller failure. | See "Getting Help" on page 147. |
|
|
|
|
E201C | SMI Init | System management interrupt | See "Getting Help" on page 147. |
|
| (SMI) initialization failure. |
|
|
|
|
|
E201D | Shutdown Test | BIOS shutdown test failure. | See "Getting Help" on page 147. |
|
|
|
|
E201E | POST Mem Test | BIOS POST memory test failure. | See "Troubleshooting System |
|
|
| Memory" on page 120. If problem |
|
|
| persists, see "Getting Help" on |
|
|
| page 147. |
|
|
|
|
E201F | DRAC Config | Dell remote access controller | Check screen for specific error |
|
| (DRAC) configuration failure. | messages. |
|
|
| Ensure that DRAC cables and |
|
|
| connectors are properly seated. If |
|
|
| problem persists, see your DRAC |
|
|
| documentation. |
|
|
|
|
E2020 | CPU Config | CPU configuration failure. | Check screen for specific error |
|
|
| messages. |
|
|
|
|
E2021 | Memory | Incorrect memory configuration. | Check screen for specific error |
| Population | Memory population order | messages. See "Troubleshooting |
|
| incorrect. | System Memory" on page 120. |
|
|
|
|
E2022 | POST Fail | General failure after video. | Check screen for specific error |
|
|
| messages. |
E2110 MBE Crd # DIMM ## & ##
One of the DIMMs in the set | See "Troubleshooting System |
implicated by "## & ##" has | Memory" on page 120. |
had a memory |
|
(MBE). If no memory card is |
|
present, the "Crd #" string is left |
|
out of the message. |
|
About Your System