Table 
| Code | Text | Causes | Corrective Actions | 
| 
 | 
 | 
 | 
 | 
| N/A | SYSTEM NAME | A  | This message is for information | 
| 
 | 
 | defined by the user in the System | only. | 
| 
 | 
 | Setup program. | You can change the system ID | 
| 
 | 
 | 
 | |
| 
 | 
 | The SYSTEM NAME displays | and name in the System Setup | 
| 
 | 
 | under the following conditions: | program. See "Using the System | 
| 
 | 
 | • The system is powered on. | Setup Program" on page 37. | 
| 
 | 
 | • The power is off and active | 
 | 
| 
 | 
 | POST errors are displayed. | 
 | 
| 
 | 
 | 
 | 
 | 
| E1000 | FAILSAFE, Call | 
 | See "Getting Help" on page 147. | 
| 
 | Support | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
| E1114 | Temp Ambient | Ambient system temperature is | See "Troubleshooting System | 
| 
 | 
 | out of acceptable range. | Cooling Problems" on page 119. | 
| 
 | 
 | 
 | 
 | 
| E1116 | Temp Memory | Memory has exceeded acceptable | See "Troubleshooting System | 
| 
 | 
 | temperature and has been | Cooling Problems" on page 119. | 
| 
 | 
 | disabled to prevent damage to the | 
 | 
| 
 | 
 | components. | 
 | 
| 
 | 
 | 
 | 
 | 
| E12nn | xx PwrGd | Specified voltage regulator has | See "Getting Help" on page 147. | 
| 
 | 
 | failed. | 
 | 
| 
 | 
 | 
 | 
 | 
| E1210 | CMOS Batt | CMOS battery is missing, or the | See "Troubleshooting the System | 
| 
 | 
 | voltage is out of acceptable range. | Battery" on page 118. | 
| 
 | 
 | 
 | 
 | 
| E1211 | ROMB Batt | RAID battery is either missing, | Reseat the RAID battery | 
| 
 | 
 | bad, or unable to recharge due to | connector. See "RAID Battery" on | 
| 
 | 
 | thermal issues. | page 74, and "Troubleshooting | 
| 
 | 
 | 
 | System Cooling Problems" on | 
| 
 | 
 | 
 | page 119. | 
| 
 | 
 | 
 | 
 | 
| E1229 | CPU # VCORE | Processor # VCORE voltage | See "Getting Help" on page 147. | 
| 
 | 
 | regulator has failed. | 
 | 
| 
 | 
 | 
 | 
 | 
| E1310 | RPM Fan ## | RPM of specified cooling fan is | See "Troubleshooting System | 
| 
 | 
 | out of acceptable operating range. Cooling Problems" on page 119. | |
| 
 | 
 | 
 | 
 | 
| E1313 | Fan Redundancy | The system is no longer fan- | Check control panel LCD for | 
| 
 | 
 | redundant. Another fan failure | additional scrolling messages. See | 
| 
 | 
 | will put the system at risk of over- | "Troubleshooting System Cooling | 
| 
 | 
 | heating. | Problems" on page 119. | 
20