[Caution] | If the N5 counter start value is beyond the counter range specified with N1 and | ||
| N2, it is assumed to be N1 = N5. If each value of N1 through N5 contains a | ||
| character code other than "0" through "9" , the printer will invalidate the data up | ||
| to that parameter and handle the subsequent data as normal print data. | ||
[Default] | N1 = 1 |
|
|
| N2 = 65535 |
|
|
| N3 = 1 |
|
|
| N4 = 1 |
|
|
| N5 = 1 |
|
|
[See Also] | GS C0, GS C1, GS C2, GS c | ||
[Sample Program] |
|
| |
| LPRINT CHR$ (&H1D) ; "C0" ; | * CNT | |
| LPRINT CHR$ (3) ; CHR$ (0) ; | FOR I=1 TO 6 | |
| LPRINT CHR$ (&H1D) ; "C" ; |
| LPRINT CHR$ (&H1D) ; "c" ; |
| LPRINT "50 ; 0 ; 5 ; 2 ; 50 ; " ; |
| NEXT I |
| GOSUB * CNT |
| LPRINT CHR$ (&HA) ; |
| LPRINT CHR$ (&H1D) ; "C ; " ; | RETURN | |
| LPRINT "50 ; 0 ; 5 ; 2 ; 5 ; " ; |
|
|
| GOSUB * CNT |
|
|
| END |
|
|
[Print Result] |
|
| When setting a |
|
|
| value = 5, repeat count = 2, and start value = 50 |
|
|
| to print a counter value. |
|
|
| When setting a |
|
|
| value = 5, repeat count = 2, and start value = 5 to |
|
|
| print a counter value. |
GS c |
|
|
|
[Function] | Printing the counter |
|
|
[Code] | <1D>H<63>H |
|
|
[Outline] | This command prints the serial number counter data. After setting the current | ||
| counter value in the print buffer as the print data (Character string), it | ||
| increments or decrements the counter according to the set count mode. | ||
[Caution] | When setting the value in the print buffer, its format depends on the GS C0 | ||
| command. The count mode depends on the GS C1 or GS C; command. If the | ||
| counter final value set with these commands if exceeded by executing the GS c | ||
| command, the counter will be initialized to the set default. | ||
[See Also] | GS C0, GS C1, GS C2, GS C ; | ||
[Sample Program] | [Print Result] | ||
| See the sample programs and print results for the commands on Pages 82 | ||
| through 85. |
|
|
87 | CITIZEN |