| Modem Command Reference |
Result Codes |
|
NO DIAL TONE | If X2 or X4 is selected and 1 second of dial tone is |
| not detected within 5 seconds; or if W dial modifier |
| is used and 3 seconds of dial tone is not detected |
| within the time specified by S7 |
BUSY | If busy is detected, and X3 or X4 is selected or if dial |
| modifier is used |
NO ANSWER | If “@” dial modifier is used and 5 seconds of |
| silence is not detected within the time specified by |
| S7 |
CONNECT XXXX | If a connection is established |
NO CARRIER | If a connection cannot be established, the abort |
| timer (register S7) expires; or a character is entered |
| during the handshake process |
En — Command Echo | |
Parameters | 0 or 1 |
Default | 1 |
Controls the echo of characters received by the modem while the modem is in the command mode. If both the modem and the software have echo on, double characters will appear. If no characters appear, then both character echoes are off.
Examples
ATE0 | Inhibits the echoing of commands |
ATE1 | Enables the echoing of commands |
Fn - Select Line Modulation (14400 only)
Parameters | 0 through 10, 13 through 19 |
Default0
This command can be used to assure that a connection is made only at the specified speed.
Examples
ATF0 | Selects |
| command) |
ATF1 | Permit V.21 or Bell 103 connections only based on |
| ATBn setting. |
ATF2 | Reserved |
User’s Guide and Reference | 4 - 9 |