Section Four
S5 — Backspace Character
Range | |
Default | 8 (Backspace) |
Sets the character recognized as a backspace. Pertains to asynchronous operation only. The modem will not recognize the Backspace character if it is set to a value that is greater than 32 ASCII. This character can be used to edit a command line. When the echo command is enabled, the modem echoes back to the local communications software the Backspace character, an ASCII space character, and a second Backspace character; this means a total of three characters are transmitted each time the modem processes the Backspace character.
S6 — Wait | Time for Blind Dialling |
Range | |
Default | 2 |
Sets the length of time to pause after the modem goes
S7 — Wait For Carrier After Dial
Range |
Default50
Defines two delay times:
1.During call establishment, this register establishes the time that the local modem waits for carrier from the remote modem before hanging up.
2.Sets the length of time that the modem waits when the "Wait For Dial Tone" call progress feature (W in the dial string) is in effect.
S8 — Pause | Time For Dial Delay |
Range |