Ositech comm Trumpcard Data/Fax Modem Set Pulse Dial as Default, Qn Result Code Display, ATQ0

Page 46

Section Four

Result Codes

CONNECT XXXX If a connection is established

NO CARRIER

If retrain is not successful in the time specified by S7

P — Set Pulse Dial as Default

Parameters none

Defaultnone

Causes the modem to assume that all subsequent dial commands are pulse dialled. The user may omit the "P" from the dial strings.

Qn — Result Code Display

Parameter

0 or 1

Default0

Determines whether or not the modem returns the result codes (see Xn command).

Examples

ATQ0

Allows the modem to return result codes

ATQ1

Prohibits the modem from returning result codes

Sn — Read/Write S Registers

Parameters

n = 0-95 x = 0-255

Default

none

Selects a S register, reads or writes the contents of a S register, or reports the value of a S register. All the S registers may be read. If no parameter is entered, S0 is assumed. The “S” can be omitted to assume the last S- register accessed.

All the registers will return the OK response if x is a legal value; however, some registers will not actually write the value anywhere.

If the parameter number is beyond the range of the S-registers available, the modem will return the ERROR message. The value x is “MOD”ed with 256, and if the result is outside the range permitted for a given S-register, the values will still be stored, but functionally, the lower and higher limits will be observed. Input and output is always in decimal format. Note that some S-registers are read-only.

In some cases, writing to the S-register will appear to be accepted but the value will not actually be written.

4 - 14

Trumpcard 14400/28800 Modem

Image 46
Contents Trumpcard Data/Fax Modem User’s Guide and ReferenceCopyright How To Contact UsFTP Preface FCC Notice Regulations Governing the Use of Modems Page Vii Contents Modem Command Reference Page Introduction Features Data ModeFacsimile Mode Cellular ModeUnique Features 22bis Industry Standards32bis MNP 42bisMNP 2, 3, 27terHardware Installation Preparing for InstallationInstalling the Trumpcard Modem Pcmcia Modem Adapter connector is keyed to go in one way Line Interface Module Connection to Telephone Network Basic Modem Operation Before You Begin Enabling The TrumpcardUsing AT Commands Operating the TrumpcardMaking an Outgoing Call Tone or Pulse DiallingStoring a Number Re-Dialling the Last NumberConnection Messages Data Connect 1200TX/75RXFAX CarrierSetting Up for a Non-Error Correcting Connection Ending Your ConnectionSetting up for a Cellular Connection Receiving an Incoming CallModem Configurations for Cellular Operation Cellular Phone Configuration Cellular Call Status Section Four Trumpcard 14400/28800 Modem Modem Command Reference Modem Command Guidelines Modem Command Reference Modem Command Summary +MSModem Command Reference Re-execute Modem Command DescriptionsAnswer ATB0 Bn Set ITU-T or Bell ModeDn Dial ATB1ATDS=2 En Command Echo Fn Select Line Modulation 14400 only+Ms Select Line Modulation 28800 only Sub-parameter DefinitionsATH0 Hn Switch-Hook ControlVFC ATH1Olume IdentificationMn Speaker Control Nn Automode Detection On Return To The On-Line StateSn Read/Write S Registers Set Pulse Dial as DefaultQn Result Code Display ATQ0Vn Result Code Form Set Tone Dial as DefaultWn Connect Message Control Xn Extended Result Codes Result Codes Q0, V1, Wn, S95 Carrier Connect Yn Control Long Space Disconnect Zn ResetCn DCD Option Dn DTR Option Restore Factory ConfigurationNone Jn T elephone Jack Selection Gn Set Guard ToneKn DTE/Modem Flow Control Qn Communication Mode Mn Communication ModePn Dial Pulse Ratio disabled for the U.S Ln Line TypeRn RTS/CTS Option Sn DSR OptionTn T est and Diagnostic AT&T7 View Configuration and User ProfilesAT&T6 AT&T8Yn Designate Default User Profile Wn Store User Profile\Gn Modem-to-Modem Flow Control Zn=x Store Phone Number\Bn T ransmit Break \Kn Break ControlAT\K3 AT\K1AT\K5 \Nn Operation Mode Control Cn Compression ControlReport Received Signal Level En Enable/Disable Line Quality MonitorReport Line Signal Quality Mn T ransmit Level Adjustment for Cellular Connection Kn MNP Extended ServicesHn Link Negotiation Speed @Mn Initial Cellular Power Level En Compromise EqualizerInit string Event Based Command Init string = NullModem S Registers Default Register SettingsModem Register Summary Modem Command Reference S95 Extended Result Codes Register Descriptions S7 Wait For Carrier After Dial S5 Backspace CharacterS6 Wait S8 PauseS11 Dtmf T one Duration S10 Lost Carrier To Hang Up DelayS9 Carrier Detect Response Time S12 Escape Code Guard TimeS25 Delay to DTR S18 Test TimerS24 Sleep Inactivity Timer S30 Inactivity TimerS33 Xoff Character S32 XON CharacterS36 Lapm Failure Control Range Default S37 Desired Telco Line SpeedS38 Delay Before Forced Disconnect S46 Protocol SelectionS48 V .42 Negotiation Action S86 Connection Failure Cause CodeS95 Extended Result Codes Class 1 Commands Facsimile CommandsClass 2 Commands Modem Test Procedures Local Modem Self-Test Local Analog Loopback Local Analog Loopback with Self- Generated Pattern Remote Digital Loopback Remote Digital Loopback with Self- Generated Pattern Local Digital Loopback Product Information Testing Modem MemoryROM Checksum Test