Section Four

 

 

ATF3

Permit V.23 1200/75 bps connections only

ATF4

Permit V.22 1200 bps connections only

ATF5

Permit V.22bis 2400 bps connections only

ATF6

Permit V.22bis or V.32 4800 bps connections only

ATF7

Permit V.32bis or V.32 7200 bps connection only

ATF8

Permit V.32bis or V.32 9600 bps connections only

ATF9

Permit V.32bis 12000 connections only

ATF10

Permit V.32bis 14400 bps connections only

ATF13

Permit V.FC 14400 bps connection only *

ATF14

Permit 16800 bps connections only

*

ATF15

Permit 19200 bps connections only

*

ATF16

Permit 21600 bps connections only

*

ATF17

Permit 24000 bps connections only

*

ATF18

Permit 26400 bps connections only

*

ATF19

Permit 28800 bps connections only

*

* Only applicable to Trumpcard 28800 version

+Ms Select Line Modulation (28800 only)

Parameters

0 through 3, 9 through 11, 64, 69, 74

Default

11

This extended-format command selects the modulation, optionally enables or disables automode, and optionally specifies the lowest and highest connection rates using one to four sub-parameters. The command format is:

+MS=<mod>[,[<automode>][,[<min.rate>][,[<max_rate>]]]]<CR>

Sub-parameter Definitions

1.<mod> = A decimal number which specifies the preferred modulation (automode enabled or the modulation (audomode disabled) to use in originating or answering a connection. the options are:

w<mod>

Modulation

Possible Rates

0

V21

300

1

V22

1200

2

V.22bis

2400 or 1200

3

V.23

1200

4 - 10

Trumpcard 14400/28800 Modem

Image 42
Contents Trumpcard Data/Fax Modem User’s Guide and ReferenceHow To Contact Us CopyrightFTP Preface FCC Notice Regulations Governing the Use of Modems Page Vii Contents Modem Command Reference Page Introduction Features Data ModeFacsimile Mode Cellular ModeUnique Features Industry Standards 22bis32bis MNP 42bisMNP 2, 3, 27terHardware Installation Preparing for InstallationInstalling the Trumpcard Modem Pcmcia Modem Adapter connector is keyed to go in one way Line Interface Module Connection to Telephone Network Basic Modem Operation Before You Begin Enabling The TrumpcardUsing AT Commands Operating the TrumpcardMaking an Outgoing Call Tone or Pulse DiallingRe-Dialling the Last Number Storing a NumberConnection Messages Data Connect 1200TX/75RXFAX CarrierSetting Up for a Non-Error Correcting Connection Ending Your ConnectionSetting up for a Cellular Connection Receiving an Incoming CallModem Configurations for Cellular Operation Cellular Phone Configuration Cellular Call Status Section Four Trumpcard 14400/28800 Modem Modem Command Reference Modem Command Guidelines Modem Command Reference Modem Command Summary +MSModem Command Reference Modem Command Descriptions Re-executeAnswer ATB0 Bn Set ITU-T or Bell ModeDn Dial ATB1ATDS=2 En Command Echo Fn Select Line Modulation 14400 only+Ms Select Line Modulation 28800 only Sub-parameter DefinitionsATH0 Hn Switch-Hook ControlVFC ATH1Identification OlumeMn Speaker Control Nn Automode Detection On Return To The On-Line StateSn Read/Write S Registers Set Pulse Dial as DefaultQn Result Code Display ATQ0Set Tone Dial as Default Vn Result Code FormWn Connect Message Control Xn Extended Result Codes Result Codes Q0, V1, Wn, S95 Carrier Connect Zn Reset Yn Control Long Space DisconnectCn DCD Option Restore Factory Configuration Dn DTR OptionNone Gn Set Guard Tone Jn T elephone Jack SelectionKn DTE/Modem Flow Control Qn Communication Mode Mn Communication ModePn Dial Pulse Ratio disabled for the U.S Ln Line TypeRn RTS/CTS Option Sn DSR OptionTn T est and Diagnostic AT&T7 View Configuration and User ProfilesAT&T6 AT&T8Yn Designate Default User Profile Wn Store User Profile\Gn Modem-to-Modem Flow Control Zn=x Store Phone Number\Bn T ransmit Break \Kn Break ControlAT\K1 AT\K3AT\K5 \Nn Operation Mode Control Cn Compression ControlEn Enable/Disable Line Quality Monitor Report Received Signal LevelReport Line Signal Quality Kn MNP Extended Services Mn T ransmit Level Adjustment for Cellular ConnectionHn Link Negotiation Speed @Mn Initial Cellular Power Level En Compromise EqualizerInit string Event Based Command Init string = NullDefault Register Settings Modem S RegistersModem Register Summary Modem Command Reference S95 Extended Result Codes Register Descriptions S7 Wait For Carrier After Dial S5 Backspace CharacterS6 Wait S8 PauseS11 Dtmf T one Duration S10 Lost Carrier To Hang Up DelayS9 Carrier Detect Response Time S12 Escape Code Guard TimeS25 Delay to DTR S18 Test TimerS24 Sleep Inactivity Timer S30 Inactivity TimerS32 XON Character S33 Xoff CharacterS36 Lapm Failure Control Range Default S37 Desired Telco Line SpeedS38 Delay Before Forced Disconnect S46 Protocol SelectionS48 V .42 Negotiation Action S86 Connection Failure Cause CodeS95 Extended Result Codes Facsimile Commands Class 1 CommandsClass 2 Commands Modem Test Procedures Local Modem Self-Test Local Analog Loopback Local Analog Loopback with Self- Generated Pattern Remote Digital Loopback Remote Digital Loopback with Self- Generated Pattern Local Digital Loopback Testing Modem Memory Product InformationROM Checksum Test