Printek 850 Series manual Copying Setup to Printer, Copying Setup To Module

Page 84

U S I N G T H E O P T I O N A L S E T U P M O D U L E

If you wish to copy the Setup data to the printer from the Setup Module, press the LOAD button. The printer will display the following message and will now be configured according to the information that was in the Setup Module.

Copying Setup to Printer

If you wish to copy the Setup data to the Setup Module from the printer, press the UNLOAD button. The printer will display the next message and the Setup Module will now contain a copy of the Setup information in the printer.

Copying Setup

to Module

After one of the above selections is made, installation is complete, the ONLINE indicator will be turned off and the printer will finish its power up procedure. If you are not sure which button to press, refer to either of the following sections for more information.

Using the Setup Module to Maintain a

Backup Copy of Setup Information for a Single Printer

This use of the Setup Module provides a method of automatically maintaining a copy of the Setup configuration in case a printer should ever need to be repaired or if it is replaced under a service contract.

To use the Setup Module in this manner, you only need to perform the installation procedure once and then forget about it. The printer will automatically keep the Setup Module updated with any changes that are made to the printer using the front panel Setup as described in “PRINTER CONFIGURATION” beginning on page 34. As long as the Setup Module remains on the same printer, the installation procedure will not have to be repeated.

If the printer does someday require repair or replacement, simply perform the installation procedure again on the repaired or replacement printer and

7 6

Image 84
Contents PrintMaster 850 Series Operator’s Manual Page Page Page Table of Contents Introduction To Setup Forms MenuInterface Menu Test MenuAscii Character Tables Specifications Glossary of Terms Page Introduction Manual Contents Lists Installation Getting StartedParallel I/O Serial I/O Interface Set Up RS-232C Serial InterfaceParallel Interface Ethernet 10/100BaseT Installing The Ribbon Cartridge Why Use Only Printek Brand RibbonsT T I N G S T a R T E D Installing a New Ribbon Cartridge T T I N G S T a R T E D Loading Paper PrintMaster 850/850si Single Tractor ModelInforming the Printer That the New Form is Loaded PrintMaster 852si Dual Tractor Model Selecting Which Form to Print Printer Self-Test Close the front lid and press the Online button Page Daily Operation IntroductionControl Panel Features LCD Display and Online Status Indicator LEDDisplay the following information Exposed Buttons Most commonly used functions LOAD/FEED Hidden Under LID Buttons Setup UnloadSelecting and Loading Forms Selecting a Form Already Loaded in the Tractors Loading a New or Different Form In the TractorsEjecting and Tearing Off a Form Tearing off a Form Aligning Print Aligning Print On InvoicesLeft/Right ←0.00→ Down/Up Left/Right ⎯0.30→Common Error Conditions Down/Up 0.08 ↓Check Paper No Paper to Load Too Much Paper to UnloadSelected Form is not Loaded Other Errors Ribbon Lid OpenPrinter Configuration Introduction To SetupSetup Buttons Entering Setup Entering Setup MenusUsing the Menu Button FormUsing the Submenu Button Using the ALIGN/ITEM and UP/DOWN Arrow ButtonsExiting Setup Exiting Menus Saving Changes No ChangesForms Menu Forms Menu ItemsForm Name Form Tractor Path RearLines/Inch Form Length 66 LinesTop Margin 0 Lines Bottom Margin 0 LinesCharacters/Inc h Left Margin ColumnRight Margin Font Epson FX FD Draft Speed NormalImpact Force Normal LanguageZero Normal Unidirectional NoInterface Menu Entering the Interface MenuSerial RS-232C Serial Interface Items Interface Menu Serial Emulation EpsonAuto CR On Auto LF OffHost FF at TOF No Characters ControlMinimum Buffer No Baud Rate Data BitsStop Bits Parity NoneDTR Power On/Off Busy Polarity LowXON/XOFF Off ETX/ACK Off Parallel/LAN Interface ItemsParallel/LAN LAN Setup Off Emulation EpsonIP Address Auto IP Address Subnet MaskIP Gateway Auto LF Off Options Menu Max Form AllowedAuto-Scroll 1 Second Delay Paper Out Fault FinishTear-Off 0.00 Inches Cannot Reprint Page Too Large will be displayed, Char. To Ignore 255 Top of Barcode OffTop Oversized Off User Language EnglishSize 8192 Characters Truncate Lines No Bottom Slew FastTest Mode Off Print MenusForm Construction and Layout Tips Form ConstructionForm Layout Considerations E C I F Y I N G F O R M S Maintenance Troubleshooting Error MessagesPreventive Maintenance Obtaining ServiceI N T E N a N C E a N D Troubleshooting Advanced Setup Features Security MenuALIGN/ITEM Edit Allowed Forms Menu Edit Allowed Interface Menu Edit AllowedOptions Menu Edit Allowed Using Remote Setup V a N C E D S E T U P F E a T U R E S Remote Setup Line Definitions V a N C E D S E T U P F E a T U R E S Remote Setup Example File V a N C E D S E T U P F E a T U R E S Using the Optional Setup Module Initializing Setup Module New Setup Module DetectedCopying Setup to Printer Copying Setup To ModuleI N G T H E O P T I O N a L S E T U P M O D U L E Printer Reset Conditions Control Code Escape Sequence Summaries Genicom 3840 and 3410 EmulationAnsi X3.64 Emulation Epson FX Emulation ESC * m n1 n2 dataESC K n1 n2 data IBM Proprinter Emulation LA-120/210 Emulation Simple TTY Emulation Printek EmulationXoff Ascii Character Tables PC Font Character Set Ebcdic Font Character Set C I I C H a R a C T E R T a B L E S OCR-B Font Character Set ML Euro C I I C H a R a C T E R T a B L E S Specifications 60 to 240 dpi horizontally x 72 dpi vertically6.7, 7.5, 8.4, 8.6, 10, 12, 13.3, 15, 16.7, 17.1, and 20 cpi 15,000,000 character, mobius loop cartridge Operator CONTROLS/INDICATORS Use of only Printek brand ribbons Specification S Glossary of Terms AsciiLCD Online Refers to the state of the printer when