Telstrat Argent manual Register settings, Register Description

Page 22

Argent Terminal Adaptor - User Guide

AT

Description

 

 

 

ATQ0 (default) Enable result codes output to the terminal.

 

ATQ1 Disables result codes to the terminal.

 

ATQ2 Disable result code in answer mode only.

\Q

Flow Control

 

AT\Q0 disables flow control

 

AT\Q1 enables XON/XOFF software flow control

 

AT\Q3 (default) enables RTS/CTS hardware flow control

%R

Read all S registers

 

AT%R Read all the S registers

%S

Serial Number

 

AT%S Read the ATA serial number

Sn?

Read S register value

 

eg ATS51? Retrieves the telephone number

Sn=

Write S register value

 

eg ATS51=6173344 5566

\T

Idle Timeout

 

Time before the link will hang up the line if no data on the connection.

 

AT\T2 sets up the timer to hang up after 2 minutes idle time

 

AT\T0 disables the idle timer so it will not cause a hang up

 

Idle Timeout can be set in minutes with valid values of 0 to 255.

VResult code format

ATV0 All results returned in short form ATV1 (default) results returned in long form

%V

ATA version number can only be read.

 

AT%V displays the version number of the software in the ATA

&V

Display current configuration

 

Shows all the current parameters

&W

Save current configuration

 

AT&W This will store the parameters even if the ATA is turned off

ZReset

ATZ resets the ATA without changing the configuration. Current calls would be lost.

+++Enter Command Mode

+++ must be a half second of no data actvity before and after “+++”.

4.3S register settings

Register

Description

 

 

S0

Auto Answer number of rings

 

ATS0=0 (default) disables answering incoming data calls

 

ATS0=n where n is a value 0 to 255 rings

S51

ATA Telephone Number

 

ATS51=6173344 5566 store the phone number to present in calls. The

 

other party on the line will see this number as your number. This number

 

must be one of the numbers issued on this connection by Telstra. MSN

Version 1.1

Telstra Corporation Limited

Page 22/29

ACN 051 775 556

Image 22
Contents Version Copyright 1999 Telstra Corporation Limited Table of Contents 24 Serial Port ‘AT’ Commands Introduction Description 3.1 ApplicationPackage Contents DefinitionsBack Panel Port FunctionsTop Panel Seven Segment Display Display InterpretationConnect ATA to NT1 ATA Activation InstructionsPrepare position Connect the Eftpos terminal to ATASelect the Required TEI Number Power-up the ATAAdjust the Display Orientation of the ATA Observe D-Channel X.25 Call Progress For the First CallObserve the Software Download Observe for Configuration File ErrorsObserve for Failure to Connect Observe that the ATA is ready and record the service details Replace the ATA if Faulty on ArrivalPoint-to-Point Protocol PPP Installation Click on Control PanelTick Don’t detect my modem I will select from list Installing Dial-Up Network Configuring Dial-Up Networking DUN Open Dial-Up Networking Double click on Make New ConnectionConnect the Eftpos terminal 17 V.120 SetupEnd to end test ATA Maintenance Warranty ATA out of Warranty with Telstra Service Assurance ‘AT’ Commands IntroductionRegister settings Register DescriptionPots Telephone Supplementary Features 5.1 Introduction Abbreviations used in the Pots feature descriptions RSPCall Waiting CW Telephone Port Pots FeaturesMalicious Call Identification Mcid / MCT Call Line Presentation Clip Call Forward Multiple Subscriber Number MSNOH DT #1# telephone number # RH