SSI America 8020, 8040 manual Overview Display, Display Survey Information

Page 17

1. Overview Display

The Overview Display shows the current readings of the five thermocouples on all four or eight boards, depending on the number of channels. Pressing the circular arrow key will display the Quick Chart screen (menu option 16). Pressing the up or down arrow keys will display the Modify Input Offsets screen (menu option 9). Pressing any of the number keys (1-9) will display the corresponding menu option.

2. Display Survey Information

The Display Survey Information shows the survey information on the top half of the screen. Included is the Template name, Company name, Furnace ID, Action (start or stop the survey), Survey Temperature Setpoint, A field to edit the survey values, The Date/Time the survey was started and the Date/Time the survey was stopped. Pressing the up or down arrow keys will scroll through the Action, Setpoint and Edit survey fields. Pressing Enter on the line “To edit survey values Press ’Enter’” will display the Modify Survey Information screen (menu option 19), which allows the user to modify some of the information used in the survey. Currently, the only information that can be modified are the Setpoint, TC units, and TC spool correction.

To start the survey, highlight the Action field, enter a 1 and then press Enter. Once a survey has been started, “Testing” will appear in the highlighted area and the start Date/Time will be filled in the “Started at” field.

Super Systems Inc.

Page 17

SDS Data Logger Manual #4565 Rev D

Image 17
Contents SDS Data Logger Product Overview5 Table of ContentsSDS Software Appendix a Standard Calibration Range Revision History98 Product Description Product SpecificationsCalibration Software InstallationVoltage connections Thermocouple connections20 mA. Current Loop connections Getting StartedSurvey Templates Page Installing the SDS Software InstallationRepair/Remove SDS Reporter screen Connecting The SDS Data Logger To a NetworkIP Address Subnet Mask Default Gateway Menu List SDS 8020/8040 Data LoggerConfiguration Level Level 2 Pass Code Required Page Keypad Assignments Display Survey Information Overview DisplayDisplay Input Settings Display Logged Data Display Input OffsetsSelect Input Channels HelpNNM Modify Input SettingsSelect Survey Template Modify Input OffsetsBattery Status Revision Display About/Sign-OnLanguage/Lengua Set Display ValuesOverview Display Selected Quick ChartModify Survey Information Quick Chart SetupSet the Date and Time Input Calibration Port SetupTC Type mV Range Chart Cold Junction Trim Firmware revision 1.09 or below Firmware Revision 1.10 and above To Perform a Cold Junction Calibration Firmware Revision 1.11 and aboveInput Board Version 1.08 and above System SetupFirmware Version 1.09 and below Set IP Address Set Pass CodesClear Logged Data Survey Deviation Alarm LogPage File Menu Options File Æ New / New ButtonSDS Reporter Report Properties Tab File Æ Open / Open ButtonPage Manually Creating a Survey Record Page 10 Report Properties Thermocouples Tab Page 14a Report Properties Furnace Tab Version 1.101.0.76 & below Page Page Page Page Page File Æ Print File Æ Save / File Æ Save As / Save ButtonFile Æ Export Page File Æ Print Preview Print ButtonFile Æ Exit SDS Æ Manage Survey TemplatesSDS Æ Download Surveys and Data Page Page SDS Æ Launch Direct FTP 36a FTP session window with Internet Explorer Ftp//LANGSSI772@IP Address FTP Login For Access to the a DriveSDS Æ View Real-time Data Page SDS Æ Manage Survey Records 43 Confirm delete of local records 45 Changes Saved message box SDS Æ Perform Comms TestPage Options Æ Show Labels On Chart Options Æ Multiple SDS ModeHelp Æ Check for Updates Options Menu OptionsHelp Æ About 54 No updates message boxSDS Data Tags 55 SDSReporter About boxTag Description Usage TC Survey SummarySdssp Tag Sample Output Sample Output TagMin/Max/Mean/Spread/Deviation Tag Description Usage TC Offsets Description Usage TagCreating a Personalized Template Page Page New Button / File Î New SDS Template ManagerOpen Button / File Î Open File Î Save As Save Buttons / File Î SaveAdd New Template Button Exit Button / File Î ExitSave Changes to Template Button Delete Template Button Template Information Tab Description of Template Manager Screen TabsSurvey Information Tab Active TCs Tab Controller Information Tab 18 New SDS Template Manager SDS Reporter Versions 1.101.0.76 and aboveSave Buttons / File Î Save Delete Button Add Template ButtonCopy Button Arrow ButtonsTemplate Information Tab Survey Information Tab Active TCs Tab Controller Information Tab Description of Template Manager Screen Fields Version 1.101.0.71 & Below General Notes Thermocouple Type Range in F Appendix a Standard Calibration RangeRevision History