SSI America 8040, 8020 manual Software Installation, Calibration

Page 6

 

Degrees F.

A/D

Accuracy

Accuracy

Accuracy

 

 

 

 

 

 

At 1600 Degrees F with

TC Type

Min

Max

Full scale

Full Scale

At 1600 Degrees F.

thermister error

 

 

 

 

 

 

 

B

32

3308

0.0124%

0.0179%

0.29

0.65

 

 

 

 

 

 

 

C

32

4208

0.0062%

0.0067%

0.11

0.47

 

 

 

 

 

 

 

E

-328

1832

0.0031%

0.0032%

0.05

0.41

 

 

 

 

 

 

 

J

-346

2192

0.0031%

0.0036%

0.06

0.42

 

 

 

 

 

 

 

K

-328

2502

0.0031%

0.0045%

0.07

0.43

 

 

 

 

 

 

 

N

-328

2372

0.0031%

0.0052%

0.08

0.44

 

 

 

 

 

 

 

NNM

0

1409

0.0031%

0.0033%

0.05

0.41

 

 

 

 

 

 

 

R

-58

3214

0.0062%

0.0118%

0.19

0.66

 

 

 

 

 

 

 

S

-58

3214

0.0124%

0.0133%

0.21

0.57

 

 

 

 

 

 

 

T

-328

752

0.0062%

0.0119%

0.19

0.55

 

 

 

 

 

 

 

*** Note: Accuracy at 1600 Degrees F with thermister error requires SDS firmware level 1.10 or later ***

Software Installation

You will find the SDS Recorder software CD that ships with the unit includes all the reporting and administrative utilities. Insert the CD into the CD ROM device on your computer and click the setup.exe file. You will be given a step-by-step instruction for completing the installation process. See Installing the SDS Software section for more details.

Calibration

The SDS data logger is calibrated prior to shipment. The calibration process is available through menu option 22 on the data logger. Instructions for calibration are included in this manual. Super Systems calibrates the SDS data logger using NIST traceable instruments that are listed on the calibration certificate included with the device. The default calibration is performed using a zero and span routine for the millivolt range of 0 – 80mV. Each range that is being used should be calibrated. For a list of suggested mV ranges by thermocouple types, please refer to the section on Input Calibration in the manual. Other calibration ranges are available upon request.

An input device will be used to input a specific type K thermocouple value and the data logger value will be recorded.

This will be performed at different temperatures and printed with the certificate.

Super Systems Inc.

Page 6

SDS Data Logger Manual #4565 Rev D

Image 6
Contents SDS Data Logger Table of Contents Product Overview5SDS Software Appendix a Standard Calibration Range Revision History98 Product Specifications Product DescriptionSoftware Installation Calibration20 mA. Current Loop connections Thermocouple connectionsVoltage connections Getting StartedSurvey Templates Page Installation Installing the SDS SoftwareConnecting The SDS Data Logger To a Network Repair/Remove SDS Reporter screenIP Address Subnet Mask Default Gateway SDS 8020/8040 Data Logger Menu ListConfiguration Level Level 2 Pass Code Required Page Keypad Assignments Overview Display Display Survey InformationDisplay Input Settings Display Input Offsets Display Logged DataHelp Select Input ChannelsModify Input Settings NNMModify Input Offsets Select Survey TemplateBattery Status About/Sign-On Revision DisplaySet Display Values Language/LenguaQuick Chart Overview Display SelectedQuick Chart Setup Modify Survey InformationSet the Date and Time Port Setup Input CalibrationTC Type mV Range Chart Cold Junction Trim Firmware revision 1.09 or below Firmware Revision 1.10 and above Firmware Revision 1.11 and above To Perform a Cold Junction CalibrationSystem Setup Firmware Version 1.09 and belowInput Board Version 1.08 and above Set Pass Codes Set IP AddressSurvey Deviation Alarm Log Clear Logged DataPage File Æ New / New Button SDS ReporterFile Menu Options File Æ Open / Open Button Report Properties TabPage Manually Creating a Survey Record Page 10 Report Properties Thermocouples Tab Page 14a Report Properties Furnace Tab Version 1.101.0.76 & below Page Page Page Page Page File Æ Save / File Æ Save As / Save Button File Æ ExportFile Æ Print Page File Æ Exit Print ButtonFile Æ Print Preview SDS Æ Manage Survey TemplatesSDS Æ Download Surveys and Data Page Page SDS Æ Launch Direct FTP 36a FTP session window with Internet Explorer FTP Login For Access to the a Drive Ftp//LANGSSI772@IP AddressSDS Æ View Real-time Data Page SDS Æ Manage Survey Records 43 Confirm delete of local records SDS Æ Perform Comms Test 45 Changes Saved message boxPage Help Æ Check for Updates Options Æ Multiple SDS ModeOptions Æ Show Labels On Chart Options Menu Options54 No updates message box Help Æ About55 SDSReporter About box SDS Data TagsTC Survey Summary Tag Description UsageSdssp Sample Output Tag Tag Sample OutputTC Offsets Description Usage Tag Min/Max/Mean/Spread/Deviation Tag Description UsageCreating a Personalized Template Page Page SDS Template Manager New Button / File Î NewOpen Button / File Î Open Save Buttons / File Î Save File Î Save AsExit Button / File Î Exit Add New Template ButtonSave Changes to Template Button Delete Template Button Description of Template Manager Screen Tabs Template Information TabSurvey Information Tab Active TCs Tab Controller Information Tab SDS Reporter Versions 1.101.0.76 and above 18 New SDS Template ManagerSave Buttons / File Î Save Copy Button Add Template ButtonDelete Button Arrow ButtonsTemplate Information Tab Survey Information Tab Active TCs Tab Controller Information Tab Description of Template Manager Screen Fields Version 1.101.0.71 & Below General Notes Appendix a Standard Calibration Range Thermocouple Type Range in FRevision History