Figure 2.7 Survey start/end date error message

Enter the TC spool offset and click on the “Add Record” button to add the record. Clicking on the “Cancel” button will cancel the add process and bring the user back to the “Load Survey Data” dialog box. If the add was successful, a message box will be displayed (figure 2.8).

Figure 2.8 Record Add successful message

The added record will be displayed chronologically in the top of the list. Any record manually added will begin with “[Manual Entry]” (figure 2.9). If the manually created survey is less than one second, it will not be displayed in the list.

Figure 2.9 Manual entry on Load Survey Data form

Note – Most of the “Report Properties” tabs (Report, Furnace, Survey Box) will need to be filled out manually as well.

The next tab is the Thermocouples tab (figure 2.10). This tab contains the information about the thermocouple settings and it also lists the active thermocouples. The information in the thermocouple settings includes: the temperature type (F or C), the number of thermocouples, the number of TCs used in the report, the thermocouple type, the thermocouple gauge, the thermocouple spool number, whom the thermocouple was calibrated by, the date the thermocouple was calibrated, and the thermocouple spool correction factor. Clicking on the “Change” button will allow the user to change the spool correction (figure 2.11).

Super Systems Inc.

Page 43

SDS Data Logger Manual #4565 Rev D

Image 43
Contents SDS Data Logger Product Overview5 Table of ContentsSDS Software Appendix a Standard Calibration Range Revision History98 Product Description Product SpecificationsCalibration Software InstallationGetting Started Thermocouple connectionsVoltage connections 20 mA. Current Loop connectionsSurvey Templates Page Installing the SDS Software InstallationRepair/Remove SDS Reporter screen Connecting The SDS Data Logger To a NetworkIP Address Subnet Mask Default Gateway Menu List SDS 8020/8040 Data LoggerConfiguration Level Level 2 Pass Code Required Page Keypad Assignments Display Survey Information Overview DisplayDisplay Input Settings Display Logged Data Display Input OffsetsSelect Input Channels HelpNNM Modify Input SettingsSelect Survey Template Modify Input OffsetsBattery Status Revision Display About/Sign-OnLanguage/Lengua Set Display ValuesOverview Display Selected Quick ChartModify Survey Information Quick Chart SetupSet the Date and Time Input Calibration Port SetupTC Type mV Range Chart Cold Junction Trim Firmware revision 1.09 or below Firmware Revision 1.10 and above To Perform a Cold Junction Calibration Firmware Revision 1.11 and aboveFirmware Version 1.09 and below System SetupInput Board Version 1.08 and above Set IP Address Set Pass CodesClear Logged Data Survey Deviation Alarm LogPage SDS Reporter File Æ New / New ButtonFile Menu Options Report Properties Tab File Æ Open / Open ButtonPage Manually Creating a Survey Record Page 10 Report Properties Thermocouples Tab Page 14a Report Properties Furnace Tab Version 1.101.0.76 & below Page Page Page Page Page File Æ Export File Æ Save / File Æ Save As / Save ButtonFile Æ Print Page SDS Æ Manage Survey Templates Print ButtonFile Æ Print Preview File Æ ExitSDS Æ Download Surveys and Data Page Page SDS Æ Launch Direct FTP 36a FTP session window with Internet Explorer Ftp//LANGSSI772@IP Address FTP Login For Access to the a DriveSDS Æ View Real-time Data Page SDS Æ Manage Survey Records 43 Confirm delete of local records 45 Changes Saved message box SDS Æ Perform Comms TestPage Options Menu Options Options Æ Multiple SDS ModeOptions Æ Show Labels On Chart Help Æ Check for UpdatesHelp Æ About 54 No updates message boxSDS Data Tags 55 SDSReporter About boxTag Description Usage TC Survey SummarySdssp Tag Sample Output Sample Output TagMin/Max/Mean/Spread/Deviation Tag Description Usage TC Offsets Description Usage TagCreating a Personalized Template Page Page New Button / File Î New SDS Template ManagerOpen Button / File Î Open File Î Save As Save Buttons / File Î SaveAdd New Template Button Exit Button / File Î ExitSave Changes to Template Button Delete Template Button Template Information Tab Description of Template Manager Screen TabsSurvey Information Tab Active TCs Tab Controller Information Tab 18 New SDS Template Manager SDS Reporter Versions 1.101.0.76 and aboveSave Buttons / File Î Save Arrow Buttons Add Template ButtonDelete Button Copy ButtonTemplate Information Tab Survey Information Tab Active TCs Tab Controller Information Tab Description of Template Manager Screen Fields Version 1.101.0.71 & Below General Notes Thermocouple Type Range in F Appendix a Standard Calibration RangeRevision History