The After Downloading option will allow the user to delete the data files from the SDS instrument, or keep them on the instrument when the files have finished downloading. Choosing the After Downloading

Keep datalog files on SDS menu option will keep the datalog files on the SDS data logger. Choosing the After Downloading Delete datalog files from SDS will delete the datalog files from the SDS data logger. Note: Once the datalog files have been downloaded to the local computer, they will not be automatically deleted by the SDS Reporter software. The only way to delete those datalog files will be to delete them manually. For SDS firmware versions 1.09 or lower (SDS menu 13 – Revision Display), it is suggested that the datalog files be periodically deleted from the SDS data logger. All survey data that is captured on the data logger is transferred to the PC using the SDS Reporter software and can be reviewed at any time from that PC. Any data logger that retains datalog files for more than one hundred ten (110) days, or roughly three and a half (3 ½) months, will begin to experience issues with the data logger. Datalog files can also be deleted by using menu option 34 on the SDS data logger (Clear Logged Data). Note – With firmware version 1.10, when the file space begins to get low, every screen will begin to flash the message “Flash Card Space Low!” at the bottom of the screen. If the file space eventually does get filled up without any data log files begin deleted, the SDS Data Logger will begin to delete the oldest files. When this happens, every screen will begin to flash the message “File Deletion is occurring!”

The SDS software will begin to download the survey data once the user has clicked on the “Download” button (figure 2.34). The button will read “Abort” while the data files are downloading. If a connection to the SDS device cannot be established, the software will display a message box informing the user (figure 2.32).

Figure 2.32 Cannot establish a connection message box

If the user chose to only download data files used in surveys, and no data files are found, the software will display an error message (figure 2.33).

Figure 2.33

The files will be downloaded to: SDS\(SDS Model number)\log(year), i.e., SDS\SDS505000\log2006.

Super Systems Inc.

Page 56

SDS Data Logger Manual #4565 Rev D

Image 56
Contents SDS Data Logger Table of Contents Product Overview5SDS Software Appendix a Standard Calibration Range Revision History98 Product Specifications Product DescriptionSoftware Installation CalibrationThermocouple connections Voltage connections20 mA. Current Loop connections Getting StartedSurvey Templates Page Installation Installing the SDS SoftwareConnecting The SDS Data Logger To a Network Repair/Remove SDS Reporter screenIP Address Subnet Mask Default Gateway SDS 8020/8040 Data Logger Menu ListConfiguration Level Level 2 Pass Code Required Page Keypad Assignments Overview Display Display Survey InformationDisplay Input Settings Display Input Offsets Display Logged DataHelp Select Input ChannelsModify Input Settings NNMModify Input Offsets Select Survey TemplateBattery Status About/Sign-On Revision DisplaySet Display Values Language/LenguaQuick Chart Overview Display SelectedQuick Chart Setup Modify Survey InformationSet the Date and Time Port Setup Input CalibrationTC Type mV Range Chart Cold Junction Trim Firmware revision 1.09 or below Firmware Revision 1.10 and above Firmware Revision 1.11 and above To Perform a Cold Junction CalibrationInput Board Version 1.08 and above System SetupFirmware Version 1.09 and below Set Pass Codes Set IP AddressSurvey Deviation Alarm Log Clear Logged DataPage File Menu Options File Æ New / New ButtonSDS Reporter File Æ Open / Open Button Report Properties TabPage Manually Creating a Survey Record Page 10 Report Properties Thermocouples Tab Page 14a Report Properties Furnace Tab Version 1.101.0.76 & below Page Page Page Page Page File Æ Print File Æ Save / File Æ Save As / Save ButtonFile Æ Export Page Print Button File Æ Print PreviewFile Æ Exit SDS Æ Manage Survey TemplatesSDS Æ Download Surveys and Data Page Page SDS Æ Launch Direct FTP 36a FTP session window with Internet Explorer FTP Login For Access to the a Drive Ftp//LANGSSI772@IP AddressSDS Æ View Real-time Data Page SDS Æ Manage Survey Records 43 Confirm delete of local records SDS Æ Perform Comms Test 45 Changes Saved message boxPage Options Æ Multiple SDS Mode Options Æ Show Labels On ChartHelp Æ Check for Updates Options Menu Options54 No updates message box Help Æ About55 SDSReporter About box SDS Data TagsTC Survey Summary Tag Description UsageSdssp Sample Output Tag Tag Sample OutputTC Offsets Description Usage Tag Min/Max/Mean/Spread/Deviation Tag Description UsageCreating a Personalized Template Page Page SDS Template Manager New Button / File Î NewOpen Button / File Î Open Save Buttons / File Î Save File Î Save AsExit Button / File Î Exit Add New Template ButtonSave Changes to Template Button Delete Template Button Description of Template Manager Screen Tabs Template Information TabSurvey Information Tab Active TCs Tab Controller Information Tab SDS Reporter Versions 1.101.0.76 and above 18 New SDS Template ManagerSave Buttons / File Î Save Add Template Button Delete ButtonCopy Button Arrow ButtonsTemplate Information Tab Survey Information Tab Active TCs Tab Controller Information Tab Description of Template Manager Screen Fields Version 1.101.0.71 & Below General Notes Appendix a Standard Calibration Range Thermocouple Type Range in FRevision History