SSI America 8040, 8020 manual Survey Templates

Page 8

Survey Templates

The data logger will default to the last survey template used. To modify the template being used, the operator can go to the Select Survey Template menu option. This data will be carried over for the reporting process to make the reporting quick and easy. On the Survey Template screen there are parameters that can be modified for a specific survey such as setpoint.

After setting the required parameters, the start survey process can be selected. This will timestamp the

selection and the data logger will log all channels that have been selected for logging.

The operator may receive deviation alarms depending on the current input and setpoint as well as the alarm settings. The alarm will notify the operator when an input is outside the plus/minus tolerance for the setpoint. The alarm information will display on the data logger and show the number of channels above tolerance and below the tolerance. The survey continues to run, it is simply providing the operator with the information on the display.

The operator can view the input channel data on a number of different screens. The overview display will display all channels on the device but by using the circular arrow key, , the operator views the overview display with only the “selected” input channels. By pressing the circular arrow key again, the operator will get the Quick Chart View screen displaying trend data for a specific channel.

At anytime, the operator can view the data in real-time from the computer using the SDS Recorder software. The real-time

data option when selected displays the data every 10 seconds. The system will update 10-second intervals every minute. Follow instructions for connecting the datalogger to the PC.

The survey can be stopped from the Display Survey Information screen. On the Action option, entering a “0” and pressing the Enter key will stop the survey.

After stopping the survey, other surveys can be taken by repeating the above steps. At anytime, all survey data can be downloaded to the PC using the Download Surveys And Data option on SDS Recorder. Follow instructions for connecting the datalogger to the PC.

Once the data has been downloaded, it is available for reporting. By clicking on the file open menu option, the operator will be given the Report dialog to generate a survey report. Reports use logged data and the user specified interval in the report. The report template selected will form the final report view with all the template data, survey data and additional report parameters that are entered.

Super Systems Inc.

Page 8

SDS Data Logger Manual #4565 Rev D

Image 8
Contents SDS Data Logger Table of Contents Product Overview5SDS Software Appendix a Standard Calibration Range Revision History98 Product Specifications Product DescriptionSoftware Installation CalibrationThermocouple connections Voltage connections20 mA. Current Loop connections Getting StartedSurvey Templates Page Installation Installing the SDS SoftwareConnecting The SDS Data Logger To a Network Repair/Remove SDS Reporter screenIP Address Subnet Mask Default Gateway SDS 8020/8040 Data Logger Menu ListConfiguration Level Level 2 Pass Code Required Page Keypad Assignments Overview Display Display Survey InformationDisplay Input Settings Display Input Offsets Display Logged DataHelp Select Input ChannelsModify Input Settings NNMModify Input Offsets Select Survey TemplateBattery Status About/Sign-On Revision DisplaySet Display Values Language/LenguaQuick Chart Overview Display SelectedQuick Chart Setup Modify Survey InformationSet the Date and Time Port Setup Input CalibrationTC Type mV Range Chart Cold Junction Trim Firmware revision 1.09 or below Firmware Revision 1.10 and above Firmware Revision 1.11 and above To Perform a Cold Junction CalibrationInput Board Version 1.08 and above System SetupFirmware Version 1.09 and below Set Pass Codes Set IP AddressSurvey Deviation Alarm Log Clear Logged DataPage File Menu Options File Æ New / New ButtonSDS Reporter File Æ Open / Open Button Report Properties TabPage Manually Creating a Survey Record Page 10 Report Properties Thermocouples Tab Page 14a Report Properties Furnace Tab Version 1.101.0.76 & below Page Page Page Page Page File Æ Print File Æ Save / File Æ Save As / Save ButtonFile Æ Export Page Print Button File Æ Print PreviewFile Æ Exit SDS Æ Manage Survey TemplatesSDS Æ Download Surveys and Data Page Page SDS Æ Launch Direct FTP 36a FTP session window with Internet Explorer FTP Login For Access to the a Drive Ftp//LANGSSI772@IP AddressSDS Æ View Real-time Data Page SDS Æ Manage Survey Records 43 Confirm delete of local records SDS Æ Perform Comms Test 45 Changes Saved message boxPage Options Æ Multiple SDS Mode Options Æ Show Labels On ChartHelp Æ Check for Updates Options Menu Options54 No updates message box Help Æ About55 SDSReporter About box SDS Data TagsTC Survey Summary Tag Description UsageSdssp Sample Output Tag Tag Sample OutputTC Offsets Description Usage Tag Min/Max/Mean/Spread/Deviation Tag Description UsageCreating a Personalized Template Page Page SDS Template Manager New Button / File Î NewOpen Button / File Î Open Save Buttons / File Î Save File Î Save AsExit Button / File Î Exit Add New Template ButtonSave Changes to Template Button Delete Template Button Description of Template Manager Screen Tabs Template Information TabSurvey Information Tab Active TCs Tab Controller Information Tab SDS Reporter Versions 1.101.0.76 and above 18 New SDS Template ManagerSave Buttons / File Î Save Add Template Button Delete ButtonCopy Button Arrow ButtonsTemplate Information Tab Survey Information Tab Active TCs Tab Controller Information Tab Description of Template Manager Screen Fields Version 1.101.0.71 & Below General Notes Appendix a Standard Calibration Range Thermocouple Type Range in FRevision History