8315 L&J Tankway Software Description | TankGate Interface |
|
|
4.10 EMU Gateway (EMUGW)
The EMU Gateway point is used to manage scanning functions for the EMU point. Statistics are maintained for the communications between the Series 8130 and the tank gauging software (TankView or System IV). Special firmware is required on the TankGate to support the emulation functions.
4.10.1Parameters
The database parameters used by the EMUGW point are listed and described below:
Configuration Parame- | Function |
ters |
|
|
|
Protocol | Protocol to emulate. Valid values are: |
| TSU Slave |
|
|
ID | Address to respond to |
|
|
Mode | Operational Mode |
|
|
BaudRate | Baud Rate used to communicate with TankView |
|
|
ComParams | Defines the number of data bits and the parity used by the com |
| port. Examples include: |
| IDAddress to respond to |
| ModeOperational Mode |
| BaudRateBaud Rate used to communicate with TankView |
| ComParamsDefines the number of data bits and the parity used by |
| the com port. Examples include: |
| 8O - 8 Data Bits Odd Parity |
| 8E - 8 Data Bits, Even Parity |
| 8N - 8 Data Bits, No Parity |
| 7O - 7 Data Bits, Odd Parity |
| 7E - 7 Data Bits, Even Parity |
| 7N - 7 Data Bits, No Parity |
| The default is ‘8N’. |
|
|
LevelConvert | Determines the units in which the level data will be displayed. F: |
| feet, M: Millimeters. If no value is specified, no conversion will be |
| performed. |
|
|
TempConvert | Determines the units in which the temperature data will be |
| displayed. F: Fahrenheit, C: Celsius. If no value is specified, no |
| conversion will be performed. |
|
|
DensityConvert | Determines the units in which the density data will be displayed. A: |
| API, L: lbs/cu ft, K: kgs/m3. If no value is specified, no conversion |
| will be performed. |
|
|
Dynamic Parameters | Function |
|
|
Message | Hex representation of the request sent by the host |
|
|
Command | Current Command |
|
|
40 | Installation and Operations Manual |