Port Access

Control

Configuration

AT-GS950/16PS Switch Web Interface User’s Guide

To configure port-based access control, perform the following procedure:

1.Select the Security folder from the main menu on the left side of the page.

The Security folder expands.

2.From the Security folder, select Port Access Control. The Port Access Control Configuration Page is displayed. See Figure 107.

Figure 107. Port Access Control Configuration Page

3. Configure the following parameters as required:

NAS ID - This parameter assigns an 802.1x identifier to the switch that applies to all ports. The NAS ID can be up to sixteen characters. Valid characters are 0 to 9, a to z, and A to Z. Spaces are allowed. Specifying an NAS ID is optional.

Port Access Control - This parameter enables or disables Port Access Control. Select one of the following choices from the pull- down menu:

Enable: The Port Access Control feature is activated.

Disable: The Port Access Control feature is de-activated.

Authentication Method - This parameter indicates the authentication method used by the switch. Select one of the following choices:

RADIUS: This parameter configures port security for remote authentication. After completing steps 4 - 6, you must configure the “RADIUS Client” on page 273.

Local: This parameter configures port security for local authentication. After completing steps 4 - 6, you must configure the parameters for “Dial-in User— Local Authentication” on page 276.

4. Click Apply when you are finished configuring the parameters.

269