AT-GS950/16PS Switch Web Interface User’s Guide

GarpLeaveAllTime - This parameter is the GARP Leave Timer.Its range si 30 - 2147483630 milli-seconds. This timer must be set in relation to the GVRP Leave Timer according to the following equation:

GARPLeaveAllTimer > (GARPLeaveTimer + 10)

Note

To ensure compatibility between network devices, you need

to configure the same values for the GARP Join Timer, GARP Leave Timer, and GARP Leave All Timer on all participating GVRP devices in your network.

5.Once you have configured the parameters, click Apply for the affected port.

6.If you want to configure the GVRP timers for other ports, repeat steps 4 and 5.

7.From the main menu on the left side of the page, select Save Configuration to Flash to permanently save your changes.

173