Terminology

What is Scanning?

Unlike standard AM or FM radio stations, most two-way communications do not transmit continuously. The UBC780XLT scans the channels you program until it finds an active frequency.

Scanning stops on an active frequency and remains on that channel as long as the transmission continues. When the transmission ends, the scanning cycle resumes until another transmission is received.

What is Searching?

The UBC780XLT can search each of its 24 bands to find active frequencies. This is different from scanning because you are searching for frequencies that have not been programmed into your scanner. The scanner automatically chooses between two speeds while searching. Turbo Search, can search the VHF FM bands at up to 300 channels per second.

What is Trunk Tracking?

Conventional scanning is a simple concept. You enter a radio frequency in your scanner’s memory which is used by someone you want to monitor. For example, the police in your area may broadcast on 460.500 MHz, the fire department on 154.445 MHz, the highway department on 37.900 MHz, etc. So when your scanner stops on a frequency, you usually know who it is, and more importantly, you can stop on a channel and listen to an entire conversation. This type of scanning is easy and fun.

As the demand for public communications has increased, many public radio users don't have enough frequencies to meet their needs, and this has created a serious problem. Trunking radio systems solve this problem.

In a trunked radio system, which contains up to 28 different frequencies, radio users are divided into groups, often called talkgroups, and these talkgroups are assigned specific IDs. When someone in a talkgroup uses their radio, a brief burst of data is broadcasted before each transmission. The trunking system computer uses this data to temporarily assign each radio in a talkgroup to an available frequency. If the group using a frequency stops broadcasting or pauses between replies for a few seconds, they are removed from the frequency so another talkgroup can use it.

Sharing of the available public service frequencies, or trunking, allows cities, counties, or other agencies to accommodate hundreds of users with relatively few frequencies. Following a conversation on a trunked system using a scanner is difficult, if not impossible. Because when there's a short break during the conversation you're monitoring, it’s possible that the talkgroup will be assigned to a completely different frequency in the trunked system. This type of scanning is difficult and frustrating.

1

Image 11
Contents UBC780XLT Important Notice IntroductionFront View and Display Rear View UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts Contents Page Terminology What is Scanning?What is Searching? What is Trunk Tracking?Page Feature Highlights Included with Your Scanner Package Optional Antenna SetupConnecting an Antenna Mounting an AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Connecting an External Speaker Desktop InstallationApplying Power Using Standard AC Power Listening Safely Connecting an EarphoneConnecting the Clone Cable Connecting the Tape RecorderTurn the Scanner On Setting the SquelchBasic Operation Understanding the Menu System 2SCREEN Mask Menu Description and Numeric Keypad Equivalents0BANK TAG 6STEPS 5PROGRAM ID 1EDIT Range 5RECORD Storing Frequencies into Channels ProgrammingAssigning a Text Tag to a Channel Duplicate Frequency AlertStoring Text Tags Assigning a Bank Tag to a BankAssigning the beep alert to a channel Beep AlertProgramming Tips Deleting a Stored FrequencyScanning To directly access a specific channelSetting the Delay Mode RF Attenuation FeatureChannel Lockout Lockout in Manual ModeLockout in Scanning Mode Priority Scan Restoring a Locked-out ChannelRestoring All Locked-out Channels Changing the Priority Channel Searching Setting a Search RangeFrequency Skip Search Hold FeatureData Skip Auto Storing Storing Search FrequenciesSquelch SQ Mode For example, the scanner shows the following displays Additional Menu Options for SearchingService Search Skip Service SearchTrunked Systems Programming Trunking Frequencies Programming and Receiving Trunked SystemsSelecting Trunking System Type Selecting Trunking Programming Menu ModeTrunked Search Receiving Trunked SystemsID Lockout ID Hold and Direct Entry ID Hold ModeTo unlock all locked out IDs in a bank at once Channel Activity IndicatorsRestoring Locked-out IDs To unlock a single ID, follow these stepsTo enter a Type I ID Scan ListsProgramming ID Scan Lists Manually To enter a LTR ID Program ID Manually with the Menu ModeTo enter an Edacs ID ID Scan Mode Moving between Scan List Memories Setting Priority in Trunking ModeProgramming Scan Lists During Search Deleting a Stored IDMotorola Type Call Motorola/EDACSMulti-Track Calls in Scan and Manual ModeScan & Search Icons Edacs Tracking Edacs ReceptionAn Edacs Trunked system AFS Partial Entry Feature Special Edacs FeaturesLTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionProgramming a Fleet Map Selecting Preset Fleet MapFleet Map Programming Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code To connect Scanner to PC Remote PC Control ModeStart Remote Mode Remote InterfaceTo connect the scanner to scanner Clone ModePC Control Parameter Change Transfer SpeedComplete displays Key Beep Option Additional FeaturesDimmer Enter LockMute On/Off Reverse ModeReceiving Mode Selection Frequency and Channel Tuning with the VFO ControlCare and Maintenance Troubleshooting Page VHF TV SpecificationsGlossary of terms Glossary of TermsPage Appendix Preset Fleet MapsS11 S12 Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesAustralian Reverse Frequency List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo UBC780XLT Shortcuts UBC780XLT Flow Charts Page UBC780XLT Flow Charts Page UBC780XLT Shortcuts Service Division One Year Limited WarrantyUBZZ01305AZ