Uniden UBC780XLT manual Reverse Mode, Mute On/Off, Record On/Off, Channel Step Selection

Page 69

Reverse Mode

This key will allow the user to observe the reverse frequency of the repeater. While pressing /RVRS, the standard pair frequency will be displayed. For a list of the standard pair frequencies, refer to the table “Reverse List” in the Appendix. If the frequency that you have chosen does not have an offset frequency, the second line will indicate the error and display

NO REVERSE. This feature does not work in the SVC Search mode.

Mute On/Off

To manually turn on the Mute function, press and hold MUTE for more than 1 second until the MUTE ON is displayed. You will not hear any audio. This feature does not function in the WX alert mode, because the audio is already muted. To turn it off, press MUTE again.

Record On/Off

It is possible for you to record every one of the 500 channels or every ID that you have programmed. (up to 1000 IDs). Once you have determined the channels or talkgroups that you want to record, you must mark them to be recorded. Through the menu system, set the RECORD ON for each channel, ID, or talkgroup using the 2:CHANNEL DATA , 3:TRUNK DATA, or 4:SEARCH EVENT menu screens. The audio signal from the TAPE OUT Jack on the rear of the scanner will be turned on for each one that was marked. When this feature is set on, the “LINE” icon appears in the display.(Refer to page 9)

Channel Step Selection

You can set channel steps, 5 kHz - 100 kHz or Auto, in Manual mode or Chain search mode. The default receive mode should be the proper mode setting in almost all cases. You may wish to set some VHF channels for NFM mode, depending on any adjacent channel interference problems. Note that WFM is typically only used for broadcast frequencies, such as TV audio or FM radio.

See “STEPS” in Menu Description for details.

Receiving Mode Selection

You can also set the receiving mode, AM or FM etc., in Manual mode or Chain search mode.

See “MODE” in Menu Description for details.

Frequency and Channel Tuning with the VFO Control

The VFO knob can be used for changing frequencies or changing memory channels (for conventional channels or talkgroup ID Scan Lists).

1.The default setting is Channel. The CHAN icon appears in the display in this setting. In Manual mode, turn the VFO control to the right (to step up through channels) or to the left (to step down through channels. If you are in Trunk Manual mode, you will step through Scan List memory locations (whether the CHAN or the FREQ icon is active).

2.To change the default setting to Frequency, press the VFO/SELECT control in Manual mode. The icon will change to FREQ. Now turn the VFO to the right to step up through frequencies sequentially or to the left to step down through frequencies. To change the step, you will need to go into the Channel Data Menu and adjust the step for the desired memory location.

59

Image 69
Contents UBC780XLT Important Notice IntroductionFront View and Display Rear View UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts Contents Page What is Searching? What is Scanning?What is Trunk Tracking? TerminologyPage Feature Highlights Included with Your Scanner Package Connecting an Antenna SetupMounting an Antenna Optional AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Desktop Installation Applying Power Using Standard AC PowerConnecting an External Speaker Connecting the Clone Cable Connecting an EarphoneConnecting the Tape Recorder Listening SafelySetting the Squelch Basic OperationTurn the Scanner On Understanding the Menu System 2SCREEN Mask Menu Description and Numeric Keypad Equivalents0BANK TAG 6STEPS 5PROGRAM ID 1EDIT Range 5RECORD Storing Frequencies into Channels ProgrammingStoring Text Tags Duplicate Frequency AlertAssigning a Bank Tag to a Bank Assigning a Text Tag to a ChannelProgramming Tips Beep AlertDeleting a Stored Frequency Assigning the beep alert to a channelScanning To directly access a specific channelSetting the Delay Mode RF Attenuation FeatureLockout in Manual Mode Lockout in Scanning ModeChannel Lockout Restoring a Locked-out Channel Restoring All Locked-out ChannelsPriority Scan Changing the Priority Channel Searching Setting a Search RangeSearch Hold Feature Data SkipFrequency Skip Auto Storing Storing Search FrequenciesSquelch SQ Mode For example, the scanner shows the following displays Additional Menu Options for SearchingService Search Skip Service SearchTrunked Systems Programming Trunking Frequencies Programming and Receiving Trunked SystemsSelecting Trunking System Type Selecting Trunking Programming Menu ModeTrunked Search Receiving Trunked SystemsID Lockout ID Hold and Direct Entry ID Hold ModeRestoring Locked-out IDs Channel Activity IndicatorsTo unlock a single ID, follow these steps To unlock all locked out IDs in a bank at onceScan Lists Programming ID Scan Lists ManuallyTo enter a Type I ID Program ID Manually with the Menu Mode To enter an Edacs IDTo enter a LTR ID ID Scan Mode Programming Scan Lists During Search Setting Priority in Trunking ModeDeleting a Stored ID Moving between Scan List MemoriesMotorola Type Call Motorola/EDACSMulti-Track Calls in Scan and Manual ModeScan & Search Icons Edacs Tracking Edacs ReceptionAn Edacs Trunked system AFS Partial Entry Feature Special Edacs FeaturesLTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionSelecting Preset Fleet Map Fleet Map ProgrammingProgramming a Fleet Map Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code Start Remote Mode Remote PC Control ModeRemote Interface To connect Scanner to PCPC Control Parameter Clone ModeChange Transfer Speed To connect the scanner to scannerComplete displays Dimmer Additional FeaturesEnter Lock Key Beep OptionReceiving Mode Selection Reverse ModeFrequency and Channel Tuning with the VFO Control Mute On/OffCare and Maintenance Troubleshooting Page VHF TV SpecificationsGlossary of terms Glossary of TermsPage Appendix Preset Fleet MapsS11 S12 Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesAustralian Reverse Frequency List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo UBC780XLT Shortcuts UBC780XLT Flow Charts Page UBC780XLT Flow Charts Page UBC780XLT Shortcuts Service Division One Year Limited WarrantyUBZZ01305AZ