Uniden UBC780XLT manual Introduction, Important Notice

Page 2

Introduction

The UBC780XLT is a state-of-the-art radio with TrunkTracking™ and automatic scanning capabilities. It can store frequencies such as police, fire/emergency, marine, railroad, air, amateur, and other communications into 10 banks of 50 channels each.

Use your new scanner to monitor:

Police and Fire Departments (including rescue and paramedics), and Ambulance Services Private and Government Trunked Systems

VHF High Band, UHF, 800MHz

Trunking for Motorola, EDACS and LTR Systems

Business/Industrial Radio

Utilities

Marine and Amateur (ham radio) Bands

Air Band

And much more...

The chart below identifies the scanner band numbers, the frequency range, the modulation mode and the default step size settings.

Band

Frequency Range

Mode

Step

No.

(MHz)

 

(kHz)

1

25.0000–27.9950

AM

5

2

28.0000–69.9900

FM

10

3

70.0000–87.9875

FM

12.5

4

88.0000–107.9000

WFM

100

5

108.0000–136.9875

AM

12.5

6

137.0000–147.9950

FM

5

7

148.0000–173.9875

FM

12.5

8

174.0000–224.9950

WFM

100

9

225.0000–399.9500

AM

50

10

400.0000–512.0000

NFM

12.5

11

806.0000–956.0000

NFM

12.5

12

1240.0000–1300.0000

NFM

12.5

Important Notice

Changes or modifications to this product not expressly approved by Uniden, or operation of this product in any way other than as detailed by this Operating Manual are violations that could void your authority to operate this product or claim warranty on this product.

The screen displays used in this manual are representations only of what will appear when you use your scanner.

This Owners Manual may include foreign terms not applicable to Australian version and conditions.

Image 2
Contents UBC780XLT Introduction Important NoticeFront View and Display Rear View UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts Contents Page What is Trunk Tracking? What is Scanning?What is Searching? TerminologyPage Feature Highlights Included with Your Scanner Package Mounting an Antenna SetupConnecting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Connecting an External Speaker Desktop InstallationApplying Power Using Standard AC Power Connecting the Tape Recorder Connecting an EarphoneConnecting the Clone Cable Listening SafelyTurn the Scanner On Setting the SquelchBasic Operation Understanding the Menu System Menu Description and Numeric Keypad Equivalents 2SCREEN Mask0BANK TAG 6STEPS 5PROGRAM ID 1EDIT Range 5RECORD Programming Storing Frequencies into ChannelsAssigning a Bank Tag to a Bank Duplicate Frequency AlertStoring Text Tags Assigning a Text Tag to a ChannelDeleting a Stored Frequency Beep AlertProgramming Tips Assigning the beep alert to a channelTo directly access a specific channel ScanningRF Attenuation Feature Setting the Delay ModeChannel Lockout Lockout in Manual ModeLockout in Scanning Mode Priority Scan Restoring a Locked-out ChannelRestoring All Locked-out Channels Changing the Priority Channel Setting a Search Range SearchingFrequency Skip Search Hold FeatureData Skip Storing Search Frequencies Auto StoringSquelch SQ Mode Additional Menu Options for Searching For example, the scanner shows the following displaysService Search Service Search SkipTrunked Systems Programming and Receiving Trunked Systems Programming Trunking FrequenciesSelecting Trunking Programming Menu Mode Selecting Trunking System TypeReceiving Trunked Systems Trunked SearchID Hold and Direct Entry ID Hold Mode ID LockoutTo unlock a single ID, follow these steps Channel Activity IndicatorsRestoring Locked-out IDs To unlock all locked out IDs in a bank at onceTo enter a Type I ID Scan ListsProgramming ID Scan Lists Manually To enter a LTR ID Program ID Manually with the Menu ModeTo enter an Edacs ID ID Scan Mode Deleting a Stored ID Setting Priority in Trunking ModeProgramming Scan Lists During Search Moving between Scan List MemoriesCall Motorola/EDACS Motorola TypeCalls in Scan and Manual Mode Multi-TrackScan & Search Icons Edacs Reception Edacs TrackingAn Edacs Trunked system Special Edacs Features AFS Partial Entry FeatureLTR Reception LTR TrackingMotorola Reception Motorola TrackingProgramming a Fleet Map Selecting Preset Fleet MapFleet Map Programming Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code Remote Interface Remote PC Control ModeStart Remote Mode To connect Scanner to PCChange Transfer Speed Clone ModePC Control Parameter To connect the scanner to scannerComplete displays Enter Lock Additional FeaturesDimmer Key Beep OptionFrequency and Channel Tuning with the VFO Control Reverse ModeReceiving Mode Selection Mute On/OffCare and Maintenance Troubleshooting Page Specifications VHF TVGlossary of Terms Glossary of termsPage Preset Fleet Maps AppendixS11 S12 User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code RestrictionsAustralian Reverse Frequency List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo UBC780XLT Shortcuts UBC780XLT Flow Charts Page UBC780XLT Flow Charts Page UBC780XLT Shortcuts One Year Limited Warranty Service DivisionUBZZ01305AZ