CHAPTER 5
OPERATOR PANEL
OVERVIEW
The printer’s Operator Panel allows you to read printer messages and change printer settings directly at the printer. The Operator Panel on the SuperScript 4600N consists of eight buttons and six indicator lights.
This chapter describes
•Operator Panel features, including indicator lights, the message display, and buttons
•Using the Operator Panel menu tree
•Important tasks you can perform using the Operator Panel and menu tree settings.
Power | Warning | Online |
| Menu | OnLine |
Data | OHT | Label |
Feed | Item | Media |
Previous | Next | Select |
OPERATOR PANEL FEATURES
Indicator Lights
The indicator lights on the Operator Panel help communicate the status of the printer.
Light | Mode | Status |
|
|
|
Power | On | Printer power is on or in POWER SAVE |
|
| mode. |
(Green) | Off | Printer power is off. |
|
|
|
Warning | On | Call for service (see page93). |
(Red) | Off | Normal state, no action is required. |
| Blinking | The printer has a problem. See the |
|
| message display. If there is no |
|
| message, call for service (see page93). |
|
|
|
Online | On | Printer is online and ready to print. |
(Green) | Off | Printer is offline or in menu mode. |
| Blinking | Printer is warming up. |
|
|
|
Data | On | Print buffer contains data. |
(Orange) | Off | Print job has ended or print buffer has |
|
| been cleared by pressing the Feed |
|
| button. |
| Blinking | Data is being sent to the printer. |
|
|
|
OHT | On | Media type is set to Over Head |
(Green) |
| Transparency (OHT). |
|
| |
| Off | Media type is not set to OHT. |
|
|
|
Label | On | Media type is set to Thick. |
(Green) | Off | Media type is not set to Thick. |
|
|
|
51